The KRFL - 1A ultra - weak chemiluminescence/bioluminescence detector is a measuring instrument specifically designed for measuring weak luminescence signals. The instrument has two measurement modes, namely energy measurement and charge integration measurement, and features a very wide dynamic measurement range. It is suitable for various analytical devices equipped with photodetectors (such as photomultiplier tubes, phototubes, photodiodes, etc.), such as chemiluminescence analysis, fluorescence analysis, and flame molecular (atomic) emission spectroscopy analysis. The instrument is internally equipped with a high - precision negative high - voltage power supply, a high - precision signal amplification and signal processing system, and a VFD digital display. The negative high - voltage power supply is dedicated to the photomultiplier tube, the signal amplifier is used to amplify and filter the signal after photoelectric conversion, the signal processing system processes the measured signal and transmits it to the system computer for analysis, and the VFD display is used to show various measurement parameters and signal values. The IFFS - A multi - functional chemical spectrophotometric detector equipped with this instrument, together with the main unit, constitutes an ultra - weak chemiluminescence/bioluminescence instrument.
Technical Features Negative High Voltage Output Voltage: - 100V to - 1000V Stability: 0.05% Output Current: ≥ 5mA Amplifier System Gain: 1X, 10X, 100X, 1000X Filter Frequency: 10Hz, 20Hz, 50Hz, 100Hz Output Drift: ≤ 0.5mV Signal Noise: ≤ 0.5mV (P - P value, 1X) Input Impedance: ≥ 10MΩ Integrating Amplifier Integration Time: 0.01 to 1000T/S Signal Processing System Sampling Rate: 1 to 1000T/S System Automatic Zero - setting Gain Automatic Control IFFS - A Multi - functional Chemiluminescence Detector Input High Voltage: - 100 to - 1000 V Wavelength Range: 300 to 650 nm (Maximum Response Wavelength: 420nm) SP > 1000 A/Lm System Software File Management: File creation, saving, reading, and selection of communication port Measurement Parameter Management: Measurement time, high voltage of the photomultiplier tube, gain selection, and filter frequency selection Spectrogram Processing: Peak value measurement (manual), area measurement (manual), spectrogram pasting, spectrogram printing, and data listing (in text format)
|
Product Tags: KRFL - 1A Chemiluminescence Detector Bioluminescence Detector Ultra weak Chemiluminescence Detector |
![]() |
UV Flue Gas Analyzer Ultra - Low Range KGD - YQ - 514 For Ultra - Low Emission Monitoring |
![]() |
KGD - WQ - 520 Ultraviolet NOₓ Emission Analyzer For Low - Emission Detection Of Vehicle Exhaust. |
![]() |
Non-Road Machinery / Diesel Vehicle Exhaust Smoke Detection System KGD-WQ-519 with Digital Output and Print Interface |
![]() |
KGD - WQ - 518 Non - Road Machinery / Diesel Vehicle Exhaust Smoke Detection System |
![]() |
KGD - WQ - 517 Non - Road Machinery / Diesel Vehicle Exhaust Smoke Detection System For Diesel Vehicle Gas Detection |
![]() |
KGD - WQ - 525 Special Calibrator for Zero Gas Generator |