Technical Parameters Of KMPI - M Electrochemiluminescence Detector
|
Technical Parameters of KMPI - M Electrochemiluminescence Detector
Product Introduction Electrochemiluminescence detection is a new type of detection method that has developed rapidly in recent years. By combining electrochemical analysis with chemiluminescence detection, it can be applied to clinical test analysis and scientific experiments in the fields of medicine, viruses, immunology, etc. The KMPI - M electrochemiluminescence detector is an integrated instrument that combines electrochemical analysis and chemiluminescence detection, featuring multiple test interfaces, multiple analysis parameters, and multiple control components. It can simultaneously conduct real - time electrochemiluminescence detection on the tested samples, and synchronously display and conduct detailed analysis of chemiluminescence signals and electrochemical analysis signals.
Application Fields Detection and analysis of drugs, amino acids, polypeptides, proteins, and nucleic acids. Research on the interactions between proteins and drugs, as well as between proteins and nucleic acids. Instrument Composition This instrument consists of three parts: an electrochemical analyzer, a multi - functional chemiluminescence detector, and a multi - functional chemiluminescence detector. The electrochemical analyzer is the core of the entire testing system. The instrument is internally integrated with a standard USB interface for communication with the system computer, which can effectively complete the data transmission between the system computer, the multi - channel data acquisition analyzer, and the corresponding control components.
Technical Features Electrochemical Analyzer It provides electrochemical methods such as potentiostat, cyclic voltammetry, and linear sweep required for electrochemical and electrochemiluminescence analysis, as well as electrochemical current detection means. Technical Specifications Potential Range: - 10 V to 10 V Current Range: ±250 mA Reference Electrode Input Impedance: 10 MΩ Sensitivity: 1 x 10⁻⁹ to 1 x 10⁻² A, a total of 8 ranges Input Bias Current: < 50 pA; Potential Increment: 1 mV Scan Rate: 0.001 to 65 V/S Multi - functional Chemiluminescence Detector Technical Specifications Measurement Dynamic Range: Greater than 5 orders of magnitude Measurement Accuracy: Better than 0.05% Amplifier Gain: 1×, 10×, 100×, 1000× Filter Frequency: 10 Hz, 20 Hz, 50 Hz, 100 Hz Amplifier Output Drift: Better than 0.05% Signal Noise: ≤ 0.5 mV (P - P value, 1×) Input Impedance: ≥ 10 MΩ Integrating Amplifier Integration Time: 0.01 to 10 seconds System Automatic Zero - setting Gain Automatic Control Sampling Rate: 1 to 200 times per second Multi - functional Chemiluminescence Detector It can perform various luminescence detections such as static injection chemiluminescence, chemiluminescence, and electrochemiluminescence, and can also be used as a shield for electrochemical detection to shield the influence of external electromagnetic interference signals. Technical Specifications Input High Voltage: - 100 to - 1000 V Wavelength Range: 300 to 650 nm (Sensitive Wavelength: 420 nm) SP > 1000 A/Lm
|
Product Tags: KMPI - M Electrochemiluminescence Detector Electrochemiluminescence Detector |
![]() |
UV Flue Gas Analyzer Ultra - Low Range KGD - YQ - 514 For Ultra - Low Emission Monitoring |
![]() |
Accurate And Customizable Micro - Flow Infrared Gas Sensor Module KGD - YQ - 536 |
![]() |
CO₂ Infrared Gas Sensor Module KGD YQ 535 for Accurate CO₂ Detection Range CO₂ 0 18% Customizable Resolution 0.0001 |
![]() |
RS 485/RS 232 Output Method Laser Sensor Module KGD YQ 534 Advanced Technology for Measurement |
![]() |
Highly Sensitive Laser Methane Sensor Module KGD YQ 533 with Tunable Diode Laser Technology |
![]() |
Infrared Gas Sensor Module KGD - YQ - 532 for Detecting Background Gases |