KMPI - EII Full - Spectrum Electrochemiluminescence Detector
|
KMPI - EII Full - Spectrum Electrochemiluminescence Detector
Product Introduction lectrochemiluminescence detection is a new type of detection method that has developed rapidly in recent years. It combines electrochemical analysis with chemiluminescence detection and can be used in clinical test analysis as well as scientific experiments in the fields of medicine, viruses, immunology, etc. The MPI - EⅡ electrochemiluminescence detector is a high - performance analytical testing device based on the Windows operating platform. This instrument can perform chemiluminescence detections such as static injection chemiluminescence, chemiluminescence, and electrochemiluminescence.
This instrument can be applied in the following fields: Detection and analysis of drugs, amino acids, polypeptides, proteins, and nucleic acids. Research on the interactions between proteins and drugs, as well as between proteins and nucleic acids. This instrument consists of two parts: the KKMPI - EII electrochemiluminescence detector and the AOL - 1 full - spectrum ultra - weak light detector. The KKMPI - EII electrochemiluminescence detector is the core of the entire testing system, and the electrochemical module and chemiluminescence module are integrated inside the instrument. The standard USB interface can effectively complete the data transmission between the system computer, the instrument, and the corresponding control components.
Electrochemistry It provides electrochemical methods such as potentiostat, cyclic voltammetry, and linear sweep required for electrochemical and electrochemiluminescence analysis, as well as electrochemical current detection means..
Technical Specifications Potential Range: - 10 V to 10 V Current Range: ±250 mA Reference Electrode Input Impedance: 10 MΩ Sensitivity: 1 x 10⁻⁹ to 1 x 10⁻² A, a total of 8 ranges Input Bias Current: < 50 pA; Potential Increment: 1 mV Scan Rate: 0.001 to 65 V/S Chemiluminescence Technical Specifications Measurement Dynamic Range: Greater than 5 orders of magnitude Measurement Accuracy: Better than 0.05% Amplifier Gain: 1×, 10×, 100×, 1000× Filter Frequency: 10 Hz, 20 Hz, 50 Hz, 100 Hz Amplifier Output Drift: Better than 0.05% Signal Noise: ≤ 0.5 mV (P - P value, 1×) Input Impedance: ≥ 10 MΩ Integrating Amplifier Integration Time: 0.01 to 10 seconds System Automatic Zero - setting Gain Automatic Control Sampling Rate: 1 to 200 times per second AOL - 1 Full - Spectrum Ultra - weak Light Detector It can perform various luminescence detections such as static injection chemiluminescence, chemiluminescence, and electrochemiluminescence, and can also be used as a shield for electrochemical detection to shield the influence of external electromagnetic interference signals. Technical Specifications Input High Voltage: - 100 to - 1000 V Wavelength Range: 230 to 920 nm (Sensitive Wavelength: 630 nm) Anode Sensitivity: > 2000 A/Lm
|
Product Tags: EII Electrochemiluminescence Detector Full Spectrum Electrochemiluminescence Detector KMPI Electrochemiluminescence Detector |
![]() |
UV Flue Gas Analyzer Ultra - Low Range KGD - YQ - 514 For Ultra - Low Emission Monitoring |
![]() |
Accurate And Customizable Micro - Flow Infrared Gas Sensor Module KGD - YQ - 536 |
![]() |
CO₂ Infrared Gas Sensor Module KGD YQ 535 for Accurate CO₂ Detection Range CO₂ 0 18% Customizable Resolution 0.0001 |
![]() |
RS 485/RS 232 Output Method Laser Sensor Module KGD YQ 534 Advanced Technology for Measurement |
![]() |
Highly Sensitive Laser Methane Sensor Module KGD YQ 533 with Tunable Diode Laser Technology |
![]() |
Infrared Gas Sensor Module KGD - YQ - 532 for Detecting Background Gases |