Advanced Gas Alarm Controller with ≤ 10W Power Consumption and ≤ 1000m Communication Distance

Advanced Gas Alarm Controller with ≤ 10W Power Consumption and ≤ 1000m Communication Distance

Brand Name KACISE
Model Number KAN121
Certification CE
Place of Origin CHINA
Minimum Order Quantity 1PCS
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Signal Transmission ABUS four - wire bus, TBUS two - wire bus
Operating Voltage AC220V ± 15%/50HZ
Alarm Threshold and Alarm Method High - limit alarm
Communication Distance ≤ 1000m (RVSP1.5mm²)
Detected Gases and Bus Capacity Combustible gases, toxic and hazardous gases, configured with 1/2/4/8 points
Power Consumption ≤ 10W (excluding detector)
Detailed Product Description

KAN121 Gas Alarm Controller

 

Product Introduction

It has two sets of built - in passive relay contact outputs, which can directly control solenoid valves and AC fans (AC220V) with a power less than 1100W. It allows for remote correction of detector sensitivity and zero - point adjustment, eliminating the need for on - site calibration using large - scale gas distribution equipment. It is equipped with an automatic fault detection function and can indicate the location and type of the fault. It can store 2000 historical records in different categories. It is optional to carry out the transformation work for a three - wire system. The system has a reserved communication interface, facilitating networking with third - party control systems.

 

Product Description

Signal TransmissionOperating VoltageAlarm Threshold and Alarm MethodCommunication Distance
ABUS four - wire bus, TBUS two - wire busAC220V ± 15%/50HZHigh - limit alarm
Low - limit alarm
Audible and visual alarm
≤ 1000m (RVSP1.5mm²)
Detected Gases and Bus CapacityPower ConsumptionControl OutputDisplay Method
Combustible gases, toxic and hazardous gases, configured with 1/2/4/8 points≤ 10W (excluding detector)Two - way programmable linkage output (contact capacity 5A/DC24V or 5A/AC220V), Pulse output: 500mS break, Continuous output: Switch - quantity output3.2 - inch 128×64 pixel dot - matrix liquid crystal LED backlit display screen, using Chinese + icon display
Under - voltage Alarm Point and Indication ErrorWorking EnvironmentDetection UnitOptional Accessories
165V ± 10V, ± 5%FSTemperature: 0°C - 40°C, Humidity: ≤ 93%RH%LEL, PPM, %VOL
mg/m³, °C, %RH
Backup battery: 2 pieces of DC12V/1.3AH storage batteries, ASD - MK5215 isolated RS485 converter
(Optional modules below) LORA, Ethernet, WIFI, NB

 

 

 

 

 

 

Product Tags: ≤ 10W Gas Alarm Controller   Advanced Gas Alarm Controller   ≤ 1000m Gas Alarm Controller  