China Fluid Level Meter manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
7
Home > Products > Gas Detector Sensor >

H2S Gas Detector - A Reliable Alternative to Alphasense

H2S Gas Detector - A Reliable Alternative to Alphasense

Brand Name KACISE
Model Number KQT-H2S
Certification CE
Place of Origin CHINA
Minimum Order Quantity 1PCS
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Load Resistance 5 - 30Ω
Detection Principle Electrochemical three - electrode
Detected Gas H₂S
Detection Range 0 - 100PPM
Maximum Load Concentration 500PPM
Resolution 1PPM
Detailed Product Description

RapidH2S Gas Detector - A Reliable Alternative to Alphasense

1.Overview

The KQT-H₂S hydrogen sulfide gas detection sensor is a constant - potential electrolysis type sensor. Hydrogen sulfide and oxygen undergo corresponding oxidation - reduction reactions on the working electrode and the counter - electrode respectively, and release charges to form an electric current. The magnitude of the generated current is proportional to the concentration of hydrogen sulfide. The concentration of hydrogen sulfide can be determined by measuring the magnitude of the current.

2. Application Fields

1.Hydrogen sulfide alarm

2.Hydrogen sulfide gas detection in industrial sites

3.Hydrogen sulfide detection in mines

4.Hydrogen sulfide detection in the atmospheric environment

3. Product Features

1.High precision and long service life

2.Fast response speed and quick return to zero

3.Low power consumption and high sensitivity

4.Wide linear range

5.Strong anti - interference ability

6.Excellent repeatability and stability

4. Technical Parameters

ProjectParameter
ModelKQT-H₂S
Detection PrincipleElectrochemical three - electrode
Detected GasH₂S
Detection Range0 - 100PPM
Maximum Load Concentration500PPM
Sensitivity650±200nA/PPM
Zero - point Drift±2PPM
Resolution1PPM
Response TimeT90< 30s
Bias Voltage0
Load Resistance5 - 30Ω
Temperature Range- 30℃ - 50℃
Humidity Range15% RH to 90% RH (no condensation)
Repeatability1% output signal
Long - term Stability< 2% signal / month
LinearityLinear, regression coefficient R² = 0.999
Working Pressure90 to 110 kPa
Shelf Life12 months after delivery
Service Life3 years

 

 