2018 Ultrasonic piezoelectric transducer sensor
|
Ultrasonic piezoelectric transducer sensor 1. Brief introduction This sensor provides very short to long-range detection and ranging, in a compact, robust PVC or stainless steel housing, designed to meet IP67 water intrusion. The power 9.0V-28V operation detects objects from 0.1meters to 10meters and provides sonar range information from 0.25meters out to 10meters out with 0.001meters or 0.01meters resolution. The interface output formats included are pulse width output, analog voltage output, NPN/PNP output and serial digital output.
2. Dimensions:(unit:mm) If the module type is M18, the dimensions are as follows,
A=Φ18.0±0.5
E=Φ12.0±0.5
3. Features 1). Designed for outdoor or indoor environments 2). High sensitivity 3). Readings can occur up to every 33mS(30Hz) within 3meters or occur up to every 80ms(12.5Hz) within 10meters. 4). Free run operation can continually measure and output ranger information 5). 9V-28V supply with very low average current draw 6). Multi-kind output type such as analog (40-20mA, 0/1-5V, 0/1-10V), RS485, Can bus. 7). Sensor operates at 40 KHz, 112 KHz, 175 KHz, 300 KHz, 1 MHz
4. Applications 1).Tank level measurement 2). Bin level measurement 3). Proximity zone detection 4). People detection 5). Robot ranging sensor 6). Autonomous navigation 7). Multi-sensors navigation 8). Distance measuring 9). Long range object detection 10). Industrial sensor
5. Package and accessories information 2 units are in box and all boxes are packed in standard packages or customers requests available. Each body of the ultrasonic is shield by foam. The dimensions of the box is 130mm*130mm*42mm.
The accessories are as follows: a, 2 meters length cable b, 2 nuts for fixing the sensor
6. Ordering information GX_US_AAA-BBB-CCC-DDD-EEE
BBB: distance range 003-30cm 005-50cm 010-100cm 030-300cm 060-600cm Others Reserved CCC: Interface Type 0V5-Analog 0-5V 1V5- Analog 1-5V 0VA- Analog 0-10V 1VA- Analog 1-10V 4MA- Analog 4-20mA SER-RS485 interface CAN-Can bus interface PUL-PUL pulse PMP-PMP pulse NON-NPN switch PNP-PNP switch Others-Reserved DDD: cable connection method Fix-fixed cable M12-M12 connection socket EEE: cable length XXX-description the cable length, the cable length should less than 15m, the number should less than 150 e.g. GX_US_S30-700-SER-FIX-080
|
![]() |
KSINC01 Current Type Inclinometer |
![]() |
Industrial Grade WSS-411W Bimetal Thermometer with Custom Stem Length |
![]() |
WSS-411W Industrial Bimetallic Thermometer |
![]() |
IP67 Fluid Level Meter Diesel Level Transmitter With GPS Tracker For Fleet Management |
![]() |
Small Capacitance Level Transmitter With RS485/4-20mA Output For Level Monitoring Of Reactor |
![]() |
KSLV606 Micro Capacitive Level Transmitter for Monitoring Plant Protection UAV Water Tank Leve |