New designed ultrasonic pressure transducer
|
New designed ultrasonic pressure transducer Product Description Features
Brief introduction of 2014 new designed ultrasonic pressure
transducer This sensor provides very short to long-range detection and ranging, in a compact, robust PVC or stainless steel housing, designed to meet IP67 water intrusion. The power 9.0V-28V operation detects objects from 0.1meters to 10meters and provides sonar range information from 0.25meters out to 10meters out with 0.001meters or 0.01meters resolution. The interface output formats included are pulse width output, analog voltage output 0/4-20mA current output, NPN/PNP output and RS485,RS232 output modbus-RTU and modbus-ASCII supported.
External synchronization The sensor can be synchronized by the external application of a square wave voltage. A synchronization pulse at the synchronization input starts a measuring cycle. The pulse must have a duration greater than 100 μs. The measuring cycle starts with the falling edge of a synchronization pulse. A low level > 1 s or an open synchronization input will result in the normal operation of the sensor. A high level at the synchronization input disables the sensor. Two operating modes are available: 1. Multiple sensors can be controlled by the same synchronization signal. The sensors are synchronized. 2. The synchronization pulses are sent cyclically to individual sensors. The sensors operate in multiplex mode. Internal synchronization The synchronization connections of up to 5 sensors capable of internal synchronization are connected to one another. When power is applied, these sensors will operate in multiplex mode. The response delay increases according to the number of sensors to be synchronized. Synchronization cannot be performed during TEACH-IN and vice versa. The sensors must be operated in an unsynchronized manner to teach the evaluation limits. Note: If the option for synchronization is not used, the synchronization input has to be connected to ground (0V) or the sensor has to be operated via a V1 cable connector (4-pin). Adjusting the evaluation limits The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage - UB or + UBto the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with - UB, A2 with + UB. Two different output functions can be set: 1. Analogue value increases with rising distance to object (rising ramp) 2. Analogue value falls with rising distance to object (falling ramp) Evaluation limits may only be specified within the first 5 minutes after Power on. To modify the evaluation limits later, the user may specify the desired values only after a new Power On. TEACH-IN rising ramp (A2 > A1) - Position object at lower evaluation limit - TEACH-IN lower limit A1 with - UB - Position object at upper evaluation limit - TEACH-IN upper limit A2 with + UB TEACH-IN falling ramp (A1 > A2): - Position object at lower evaluation limit - TEACH-IN lower limit A2 with + UB - Position object at upper evaluation limit - TEACH-IN upper limit A1 with - UB Default setting A1: unusable area A2: nominal sensing range Mode of operation: rising ramp Adjusting the sound cone characteristics of 2014 new designed ultrasonic pressure transducer: The ultrasonic sensor enables two different shapes of the sound cone, a wide angle sound cone and a small angle sound cone. 1. Small angle sound cone - switch off the power supply - connect the Teach-input wire to -UB - switch on the power supply - the red LED flashes once with a pause before the next. - yellow LED: permanently on: indicates the presence of an object or disturbing object within the sensing range - disconnect the Teach-input wire from -UB and the changing is saved 2. Wide angle sound cone - switch off the power supply - connect the Teach-input wire with + UB - switch on the power supply - the red LED double-flashes with a long pause before the next. - yellow LED: permanently on: indicates an object or disturbing object within the sensing range - disconnect the Teach-input wire from + UB and the changing is saved Installation conditions If the sensor is installed at the environment temperature fall below 0°C,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread. Feedback
Packaging & Shipping of 2014 new designed ultrasonic pressure
transducer Package and accessories information 2 units are in box and all boxes are packed in standard packages or customers requests available. Each body of the ultrasonic is shield by foam. The accessories are as follows: a, 2 meters length cable b, 2 nuts for fixing the sensor
Ordering information
Our Services other related products
FAQ
FAQ This product is not proper for me,could you please introduce me a some ohter one suitable to me? Of course, Please have a look at our product by click the ultralink below. http://xagx.en.alibaba.com/productgrouplist-218815808/Ultrasoinc_Transducer.html |
![]() |
KLD801 Radar Level Gauge For Non-corrosive Liquids Is Used For Level Monitoring Of Non-corrosive Liquids |
![]() |
KLD802 Radar Level Gauge For Slightly Corrosive Liquids For Slightly Corrosive Liquids Monitoring |
![]() |
High Temperature And High Pressure Corrosion Resistant Capacitive Level Sensor For Boiler Level Monitoring |
![]() |
IP67 Fluid Level Meter Diesel Level Transmitter With GPS Tracker For Fleet Management |
![]() |
Corrosion Resistant Capacitive Level Transmitter With NPN/PNP Output Is Used For Level Monitoring In Laboratory Reactors |
![]() |
Small Capacitance Level Transmitter With RS485/4-20mA Output For Level Monitoring Of Reactor |