Waterproof Online Water Turbidity Meter Anti Interference
|
Scattering Method Online Turbidity Sensor Anti InterferenceKTU310 Online Turbidity Sensor 90 ° Angle Scattering Principle Fiber Structure, Strong Anti-Interference Ability1.PrincipleThe KTU310 integrated online turbidimeter is designed and made by the principle of scattering light turbidimeter. When a beam of light enters a water sample, the light is scattered by the turbidity material in the water sample. The turbidity in the water sample can be calculated by measuring the intensity of the scattered light in the vertical direction of the incident light and comparing it with the internal calibration value, the final value is output after linearization. 2.Feature90 ° angle scattering principle, built-in temperature sensor Support RS-485, Modbus/RTU protocol Fiber structure, the strong anti-interference ability of external light The infrared LED light source, high stability IP68, shield, water depth, 20 meters Convenient, fast, stable, and easy to maintain 3.Technical Specifications
4.Dimensional DrawingTips: AMI Turbiwell
The EPA approved alternative method non-contact nephelometer
This method is unique in that it is an EPA-approved turbidity monitoring method for a non-contact turbidimeter 49. As a non-contact, or surface scatter, nephelometer, the AMI Turbiwell is intended for continuous monitoring, like other process or online monitoring instruments. Until 2009, no surface-scatter design was approved by the USEPA. This design requires that the light source be an LED with a spectral response between 400 and 600 nm. The incident light beam should be angled to reach the water’s surface at a 45-degree angle, +/- 5 degrees. A beam splitter should be used to deflect a small portion of this light beam before it hits the water. This deflected beam is used as a reference signal to monitoring light intensity. The primary photodetector is set at a right angle to the light source and should have a peak spectral response between 400-600 nm. An algorithm then determines turbidity levels based on the light intensity of the scattered and reference signals. Though it is a surface-scatter design, the total distance traveled
by the light beam (from the LED source to the photodetector) should
not exceed 10 cm. To be approved by the EPA, this method can only
be used for the range of 0-40 NTU. However, the nephelometer itself
can be used up to 200 NTU, though these readings will not be
considered EPA-compliant. |
||||||||||||||||||||||||||||
Product Tags: Waterproof Water Turbidity Meter Anti Interference Water Turbidity Meter |
![]() |
KWS-850 On-line Multi-parameter Water Sensor High Accuracy Turbidity Measurement For Wastewater Treatment Plants |
![]() |
Power Consumption 5W 12V KWS-850 Multi-Parameter Water Quality Sensor For Water Monitoring |
![]() |
Low Maintenance Of The KWS-850 On-line Multi-parameter Water Quality Sensor |
![]() |
Precision KWS-850 On-line Water Turbidity Sensor Water Quality Sensor For Aquaculture |
![]() |
The KWS-850 On-line Multi-parameter Water Quality Sensor Can Measure 8 Parameters Simultaneously |
![]() |
The Integrated KWS-850 On-line Multi-parameter Self-cleaning Digital Digital Sensor |