RTU Protocol Water Turbidity Sensor For Monitoring Red Algae
|
KBG602 Online Blue Green Algae Sensor Support RS-485 Modbus/RTU Protocol Monitoring Red Algae1.Working PrincipleThe blue green algae sensor utilizes the characteristic that the blue green algae has an absorption peak and an emission peak in the spectrum. The spectral absorption peak of the blue green algae emits monochromatic light to the water, and the blue green algae in the water absorbs the energy of the monochromatic light, releasing another wavelength. The monochromatic light of the emission peak, the light intensity emitted by the blue green algae is proportional to the content of blue green algae in the water. 2.Feature
3.Technical Specifications
4.Dimensional Drawing 5. Installation and Electrical Connection |
Maintenance task | Recommended maintenance frequency |
Calibrate the sensor (if required by the competent authority) | According to the maintenance schedule required by the competent authority |
6.1.2 Maintenance Methods
- Sensor outer surface: Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft, damp cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.
- Check the cable of the sensor: the cable should not be tightened during normal operation. Otherwise, the internal cable of the cable may be broken and the sensor may not work normally.
- lCheck the sensor's measurement window for dirt.
6.1.3 Precautions
The probe contains sensitive optical and electronic components.
Make sure the probe is not subject to severe mechanical shock.
There are no parts inside the probe that require user maintenance.
6.2 Sensor Calibration
a) Zero calibration: Take a proper amount of distilled water in a
large bucket and place the sensor vertically in the solution. The
front end of the sensor is at least 20 cm away from the bottom of
the beaker. After 3 to 5 minutes, the value is stabilized and the
zero point is calibrated. The instructions refer to the appendix.
b) Slope calibration: Place the sensor probe in the standard
solution. The front end of the sensor is at least 20cm away from
the bottom of the beaker. After 3 to 5 minutes, the slope is
calibrated after the value is stable. The instructions refer to the
appendix.
6.3 Frequently Asked Questions
Error | Possible Reason | Solution |
The operation interface cannot be connected or the measurement result is not displayed. | The measured value is too high, too low or the value is continuously unstable | Reconnect controller and cable |
Cable failure | Please contact us | |
The measured value is too high, too low or the value is continuously unstable | The sensor window is attached by a foreign object | Cleaning the sensor window surface |
7.Quality and Service
7.1 Quality Assurance
- The quality inspection department has standardized inspection procedures, advanced and perfect
testing equipment and means, and strictly in accordance with the regulations, to do 72-hour aging test and stability test on the product, and not to allow one unqualified product to leave the factory.
- The receiving party directly returns the product batch with a failure rate of 2%, and all the costs incurred are borne by the supplier. The reference standard refers to the product description provided by the supplier.
- Guarantee the quantity of goods and the speed of shipment.
7.2 Accessories Spare and Parts
This product includes:
- 1 sensor
- Calibration powder 3 packs
- 1 copy of the manual
- 1 certificate
7.3 After-sales Service Commitment
The company provides local after-sales service within one year from
the date of sale, but does not include damage caused by improper
use. If repair or adjustment is required, please return it, but the
shipping cost must be conceited. Damaged on the way, the company
will repair the damage of the instrument for free.
Contact Us
Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi
Province, China
![]() |
KWS-850 On-line Multi-parameter Water Sensor High Accuracy Turbidity Measurement For Wastewater Treatment Plants |
![]() |
Power Consumption 5W 12V KWS-850 Multi-Parameter Water Quality Sensor For Water Monitoring |
![]() |
Low Maintenance Of The KWS-850 On-line Multi-parameter Water Quality Sensor |
![]() |
Precision KWS-850 On-line Water Turbidity Sensor Water Quality Sensor For Aquaculture |
![]() |
The KWS-850 On-line Multi-parameter Water Quality Sensor Can Measure 8 Parameters Simultaneously |
![]() |
The Integrated KWS-850 On-line Multi-parameter Self-cleaning Digital Digital Sensor |