China Fluid Level Meter manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
7
Home > Products > Water Quality Sensor >

Extendable KPH500 14PH 2000mv Water Quality Sensor

Extendable KPH500 14PH 2000mv Water Quality Sensor

Brand Name kacise
Model Number KBU601
Certification CE,FDA
Place of Origin CHINA
Minimum Order Quantity 0-100
Price $100-$2000
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100
Delivery Time 10-15 days
Packaging Details Common package or custom package
Sensor:Protection Level ip68
Sensor:Temperature 0-60°C
Sensor:Material PVC
Sensor:Cable Length Dedicated PH cable, standard 5 meters (extendable)
Sensor:Operating Temperature 0-60°C
Sensor:Storage Temperature -10-60°C
Detailed Product Description

KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

Production Introduction
The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is widely used in agriculture, environmental protection and industry.
 
 
 
The sensor uses a composite electrode, which can eliminate the influence of the inconstant "K" value,
A long-term, stable and accurate measurement of PH is realized. The internal structure of the sensor is shown on the right.
 
 

 
 
 

 

 
 
 

 

PH/ORP size structure chart
 
Host size
 
 
 

 
 
Sensor size
 

 

 

 


 

PH/ORP technical parameters
 
 
 

ClassPerformancePH parameterOPR parameter
HostMeasuring range0-14PH-2000mv-2000mv
Resolution0.01PH1mv
Precision2% Calibration accuracy
Operating TemperatureTransmitter 0-65℃
MaterialPVC
Protection LevelI65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Supply VoltageAC220V or DC24V (choose one of the two)
Power Consumption<1W
DisplayLCD Chinese display/TFT color LCD (customized version)
Installation MethodWall mount
SensorTemperature CompensationAutomatic temperature compensation
Protection Levelip68
Temperature0-60℃
Sensor MaterialPVC
Cable LengthDedicated PH cable, standard 5 meters (extendable)
Operating Temperature0-60℃
Storage Temperature-10-60℃
Installation MethodBracket drop-in installation

 
 
 
 

Ordering Information Selection Table
KPH500PH/ORP analyzer
Power supplyDC24V
AC220V
Cable length5m
10m
15m
20m
Temperature compensationSensor without temperature compensation
Sensor with temperature compensation
Signal outputOnly 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

Optional ORP host, with 220V adapter, line between host and sensor
The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.

 

Q&A

1.Can alkaline kill bacteria?

Raising pH (to an alkaline state) increases the immune system's ability to kill bacteria, concludes a study conducted at The Royal Free Hospital and School of Medicine in London. The viruses and bacteria which cause bronchitis and colds thrive in an acidic environment.

 

 

2.What pH kills E coli?

Previous studies have demonstrated the ability of E. coli O157:H7 to survive pH 3.0 for 2 to 5 h (2, 5, 8, 15). In this study, we have demonstrated the ability of a nontoxigenic strain of E. coli O157:H7 to survive prolonged exposure to pH 3.0.

 

3.How can I make my body more alkaline?

Most fruits and vegetables, soybeans and tofu, and some nuts, seeds, and legumes are alkaline-promoting foods, so they're fair game. Dairy, eggs, meat, most grains, and processed foods, like canned and packaged snacks and convenience foods, fall on the acid side and are not allowed.

 

4.What happens if the pH of your blood changes?

An increase in alkaline causes pH levels to rise. When the levels of acid in your blood are too high, it's called acidosis. When your blood is too alkaline, it is called alkalosis. Respiratory acidosis and alkalosis are due to a problem with the lungs.

 

Avoiding harsh soaps and douching. Soaps typically have a high pH, and using them to clean the vaginal area may increase vaginal pH. ...

Taking a probiotic supplement or suppository. ...

Changing tampons regularly. ...

Using barrier protection during sex.

 

5.What pH is safe to touch?

The optimal pH of human skin is 5.5 and you can measure it with a piece of litmus paper. Your sweat with the sebum on your skin to form something called an acid mantle, which has a pH of 4 to 5.5.

 

 

 

 

Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 
 

Product Tags: 2000mv Water Quality Sensor   14PH Water Quality Sensor   ip68 Extendable Water Quality Sensor  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Xi'an Kacise Optronics Co.,Ltd.
Subject:
Message:
Characters Remaining: (80/3000)