4000 NTU Lightning Proof 316L 0.6MPa Water Quality Sensor
|
KLT900 online Lightning proof enclosure turbidity meter 316L stainless steel sensor Production Introduction
The optical method is often used to measure the turbidity of liquid by comparing with the standard turbidity.The turbidimeter uses the principle of 90° scattered light to accurately measure the turbidimetric value of the tested sample compared with the standard Turbidimetric solution of Formazin. With its unique software function, the scattered light turbidimeter ensures the accuracy and reliable stability of the instrument.It is widely used in the determination of liquid turbidity in industrial and mining, medical treatment, environmental protection, food, brewing, textile, chemical and other departments. The ratio of scattered light to transmitted light is taken to measure the turbidity of liquid.The tungsten lamp as light source, light through the lens and color filter, all the way through the measured turbidity liquid transmission to cell 1 received, the other all the way through the liquid 2 receive 90 °scattering to the cell, acoustic signal by the op-amp signal processing after A/D conversion, data processing by single chip microcomputer, through the keyboard control measurement showed that the liquid turbidity value and print output.
Measuring principle
TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.
Turbidity meter size structure diagram
host size
sensor size
Turbidity meter technical parameters
Ordering Information Selection Table
Calibration The standard turbidity liquid of 20NTU, 100NTU, 200NTU and 400NTU has been preliminarily calibrated before the delivery of the scattered light turbidimeter,to adjust the multi-section gain and store in EPROM. After the delivery of the turbidimeter, according to the turbidity liquid measured, the standard turbidity liquid is appropriately selected for accurate calibration: (1) Sample <20NTU: 20NTU standard turbidity solution was selected; (2) 20NTU< sample <100NTU: 100NUT standard turbidity solution was selected; (3) 100NTU< sample under test <200NTU: 200NTU standard turbidity solution was selected; (4) 200NTU< sample under test <400NTU: 400NTU standard turbidity solution was selected.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 0.6MPa Water Quality Sensor 4000 NTU Water Quality Sensor 316L Water Quality Sensor |
![]() |
KWS-850 On-line Multi-parameter Water Sensor High Accuracy Turbidity Measurement For Wastewater Treatment Plants |
![]() |
Power Consumption 5W 12V KWS-850 Multi-Parameter Water Quality Sensor For Water Monitoring |
![]() |
Low Maintenance Of The KWS-850 On-line Multi-parameter Water Quality Sensor |
![]() |
Precision KWS-850 On-line Water Turbidity Sensor Water Quality Sensor For Aquaculture |
![]() |
The KWS-850 On-line Multi-parameter Water Quality Sensor Can Measure 8 Parameters Simultaneously |
![]() |
The Integrated KWS-850 On-line Multi-parameter Self-cleaning Digital Digital Sensor |