Water Treatment Water Quality Sensor Residual Chlorine Hclo Probe Sensor
|
KWS-3000 12V/24V High Accuracy RS485 Output Water Quality Sensor On-line Residual Chlorine HCLO Probe Sensor1. Applications
Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project.
2. Feature
3. Technical Specifications
4. Outline
5. Electric Connect
The electrode should be installed closely with the circulation pool. The electrode measurement part should be placed in the area near the circulation pool inlet. It is not allowed to face the outlet. Ensure the smooth flow . We suggest to control the flow rate within 30-60l /h to ensure the test accuracy. Red: Power supply (12~24V) Black: Ground(GND) Blue: 485A White: 485B Exposed wire: shielded wire Please make sure that you connect the wire correctly. Cable specifications: the cable has a certain corrosion resistance, considering that it has been immersed in water (including seawater) or exposed to air for a long time. The diameter is Φ6 mm. Please make the waterproof processing on cable joint.
5. Maintenance
1) Sensor detection and maintenance The new electrode and the electrode placed for a long time should be activated before use. The sensor shall be left in the tap water for 24 hours.If the returned value is not correct, please make the following operation.
2) Calibration of sensors a) zero point calibration: the sensor probe is placed in chlorine-free water for zero point calibration after the numerical stability. B) slope calibration: the sensor probe is placed in the flow pool with residual chlorine standard liquid, and the slope calibration is performed after the value is stable. Suggest to use 1-2mg/L HCIO standard solution. About the preparation and determination of the standard liquid, we can refer to the determination of residual chlorine standard. Note: the sensor has been calibrated before delivery. Since the preparation of its standard liquid has high requirements on personnel, non-professionals may not be qualified for this job. Only if the value is determined to be inaccurate, it is recommended that the user do not calibrate the sensor.
|
||||||||||||||||||||||||||||||
Product Tags: water turbidity sensor oil in water sensor |
![]() |
Low Maintenance Of The KWS-850 On-line Multi-parameter Water Quality Sensor |
![]() |
KWS-850 Water Quality Sensor For Simultaneous Measurement Of Dissolved Oxygen / COD / Conductivity |
![]() |
KWS-850 On-line Multi-parameter Water Sensor High Accuracy Turbidity Measurement For Wastewater Treatment Plants |
![]() |
Power Consumption 5W 12V KWS-850 Multi-Parameter Water Quality Sensor For Water Monitoring |
![]() |
KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement |
![]() |
Scattered Light Method KWS-950S Online TSS Sensor For 0 To 2000 Mg/L Range |