Brand Name Techcore
Model Number OMNI 515008A
Certification ISO, BV, SGS
Place of Origin CHINA
Minimum Order Quantity 1 set
Price Negotiable
Supply Ability 50sets/month
Delivery Time 30-45 days
Packaging Details Polly wood, suitable for sea and air shipment
Tool Size 5 inch
Working Pressure 15000 psi
Material Inconel
Connection CAS BxP
Standard NACE MR0175
Working Condition Full H2S connection
Application Drill Stem Testing Operation
Type Multi cycle circulating
Detailed Product Description

High Pressure RD Circulating Valve Full H2S Service Well Testing DST Tool

 

Introudction of Multi Cycle Circulating Valve

 

Multi-cycle circulating valve is a kind of circulating valve, which is used in well testing service. The valve made of Inconel alloy steel is served in Full H2S well condition. The multi-cycle circulating valve is acceptable for the full-opening formation testing in cased hole, oil tube tradition perforation, tube string testing and cycle operation in the conjunction of perforation and full-opening formation testing. The multi-cycle circulating valve overcomes the shortcomings of some other circulating valve, at a certain position, can use the annulus pressure to operate other tools many times and there is no influence upon the multi-cycle circulating valve

 

Working principle of Multi Cycle Circulating Valve

 

Multi-cycle circulating valve completes the function by increasing and releasing the annulus pressure .

According to the construction features it can be learned when increasing the annulus pressure, the piston push the hydraulic oil to move to the left, and the hydraulic oil push the check valve assemblies to move to the left until to the upper dead point, then the hydraulic oil pass the passageway and push the floating piston in the nitrogen chamber, thus the pressure is saved in the nitrogen chamber.

When releasing the pressure, because the pressure in nitrogen chamber is above the annulus

pressure ,the nitrogen pressure push the floating piston in the nitrogen chamber and then to hydraulic oil move to the right, the check valve assemblies to move to the right under pushing of hydraulic oil until

to the lower dead point, the hydraulic oil make the nitrogen pressure equal to the annulus pressure.

 

 

Technical parameter of Multi-cycle circulating valve

NoSpecification5”
1OD127.5mm
2ID57mm
3Length6555mm
4Working pressure105Mpa
5Internal Pressure strength146Mpa
6External pressure strength136Mpa
7Tensile strength2034KN
8Torque strength31.6KN.m
9Circulating Flow area2280mm2
10ServiceFull H2S
11Working temperature-29℃~+204℃
12Connection thread3 7/8″CAS.B×P or 3 1/2″IF.B×P

 

 

Well Testing Multi Cycle Circulating Valve High Pressure Full H2S Service DST

 

HSE﹡Safety instructions:

 

* When running each pressure test,  the pressure must be increased gradually. When the pressure is up

   to 20MPa, hold on for one minute, then every 10MPa keep it for one minute until the rating pressure;

* During pressure testing, the DST tool should be placed in the test pit and cover the protecting board on 

  the pressure test plug.

* During the whole testing process, make sure the entire test operator keep away from plug and joint

  which may lapse.

* Test area should set isolation, others except operator not allowed to enter test area.

* If there is anybody in the test area, it should set isolation, avoiding test production fly off the test area.