China Downhole Oil Tools manufacturer
Techcore Oil Tools Co.,Ltd,
Professional Provider & Manufacture of DST tools, Coiled Tubing Tools & Wireline Tools
7
Home > Products > Select Tester Valve >

5" 15000 PSI Downhole Select Tester Valve Full H2S Well Testing Service

5" 15000 PSI Downhole Select Tester Valve Full H2S Well Testing Service

Brand Name Techcore
Model Number STV515005A
Certification ISO, BV
Place of Origin CHINA
Minimum Order Quantity 1 set
Price Negotiable
Supply Ability 20sets/month
Delivery Time 30-45 days
Packaging Details Polly wood, suitable for sea and air shipment
Application Well testing
Working Pressure 15000 psi
Tool Size 5"
Connection CAS BxP; IF BxP
Standard NACE MR0175
Working Condition Full H2S service
Material Inconel
Type APR tools
Detailed Product Description

5" 15000 PSI Downhole Select Tester Valve Full H2S Well Testing Service

 

Introudction of DST Select tester valve

 

The select tester valve is the lock open tester valve with a full opening design and operated by annulus pressure which is used drill stem testing operation in cased holes. The tester valve is able to take multiple downhole closures where pipe manipulation is restricted, and the tool can be locked open and then

returned to the normal operating sequence at any time

The select tester valve is composed of four basic sections: ball valve section, nitrogen section, upper hydraulic section,  and the metering section.

 

Features of the DST tester valve

 

* The select tester valve is able to lock the ball valve in the open position at any point during the string

   test operation

* With metal to metal seal for exceptional gas-holding capabilities

* The select tester valve made of Inconel alloy steel can work in the Full H2S service

* The tool can be locked open to allow operation of other services, including coil tubing, wire line,

   slick line and well kill operations

 

Specification of the Select tester valve

 

NO.Specification5”
1OD5”
2ID2.25”
3Length(mm)288.2”
4Working pressure15000 PSI
5Torque strength30.9kN.m
6Service EnvironmentFull H2S service
7End connection3 7/8CAS. BXP, 3 1/2 IF BXP
8Service temperature-20oF~450oF

 

Operation of the tester valve

 

Under normal operating conditions the tool would be run in the well in the closed position. Once the packer is set, pressure is applied to the annulus to operate the tester valve.

The select tester valve has a spring loaded normally closed ball valve. Spring force holds the valve in the closed position. By applying additional pressure to the annulus, the tester valve is opened and maintained open . When applied annulus pressure is released, the ball valve will close. Fluid at hydrostatic pressure is trapped behind the nitrogen chamber acting against a piston, compressing the nitrogen to hydrostatic pressure. The nitrogen then acts against the lower piston, the same hydrostatic pressure that is acting against the lower piston is also passing through pressure ports, located in the upper outer housing acting against the upper piston. Both the upper and lower piston have the same cross-sectional area, thus keeping the ball valve balanced.

 

Select tester valve metering

 

Techcore Oil Tools expertise in manufacture of the DST tools for more than Ten years, the professional Reserch and Development (R&D) department improves the advanced technology in design of the downhole oil tools for well testing service and well completion service.

 

We approach every client’s enquiry with meticulous attention to technical specifications, and a high level of appreciation for their urgency.

 

Welcome to contact us for more informaiton!

Product Tags: downhole valve   pressure safety valve  