12 Months Warranty Fire Testing Equipment BS476-6 Standard
|
Detailed Product Description
BS476-6 Fire Tests Fire Propagation Tests On Building Materials And
Structures BS476-6 Fire propagation Tests on Building materials and structures Model: DX8298 Meet the standards: BS 476 Part 6 specifies a method of test for providing a comparative measure of a flat material or assembly's contribution to the growth of a fire. Scope of application: Fire spread index to evaluate the performance of interior wall and
ceiling lining. 1. Indoor wall materials; 2. Thermal insulation materials; 3. Ceiling materials. Technical parameters: Combustion chamber: Chamber wall:
Test procedure: -Turn on the gas source and use the gas igniter to ignite the nozzle; -Start timing from ignition; -After 2 minutes and 45 seconds, turn on the power and input 800 W; -After ignition for 5 minutes, the indication input decreases to 1500 W. |
||||||||||||||
Product Tags: Fire Testing Equipment BS476-6 12 Months Warranty Fire Testing Equipment |