5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ
|
Construction Materials Fire Resistance Thermal Conductivity Testing Equipment
Scope of application: Thermal conductivity of dry test pieces of clay and sand, the thermal resistance of the sample should be greater than 0.1m2.K / W. A thermal flow meter is used to detect the thermal conductivity and thermal resistance of clay, sand, etc., and the computer is used to realize automatic detection and generate an experimental report. The instrument adopts a stable hot surface temperature on the side of the sample, and the heat is transferred to the cold surface (room temperature) through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Specially equipped with geotechnical sample cylinder and specific heat capacity test device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.
Standard: It conforms to GB / T10295-2008 "Determination of Steady State Thermal Resistance and Related Characteristics of Thermal Insulation Materials" and ISO / DIS8301 "Insulation-Determination of Steady State Thermal Resistance and Related Characteristics-Heat Flow Meter Device".
Technical parameters: 1. Thermal conductivity range: Plate-like sample 0.015-400W/mk, accuracy better than 5%; Cylindrical sample 3-400W/mk, accuracy less than 5%; (A round sample cylinder with rock-finish soil, Ф90mm) 2. Hot surface temperature: room temperature -99.99 °C, the use of high digital display meter temperature measurement, 0.2 precision, resolution 0.01 °C. 3. Cold surface temperature: room temperature, using a high digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C. 4. Hot surface temperature control: room temperature -99.99 °C, using a high number of digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C, flat heater, two-way SCR control. 5. Cold forced air cooling. The cold side is water-cooled to ensure stable cold face temperature (optional for temperature users) 6. Using computer automatic testing. 7. Heat flow range: 0.5-2000W/m2, delivery rate of 0.25 W/m2. 8. Using WPY heat flow meter, heat flow parameters 23.26w/m2.mV. 9. Using plexiglass windshield, can directly observe the experimental process. 10. Uot and cold plate heat transfer area: 150 × 150 (mm), (can be manufactured according to user requirements 300/300,600/600 and other specifications of the sample). 11. Adjustable hot and cold plate spacing: 0-160 (mm).
The main technical parameters:
|
||||||||||||||||
Product Tags: thermal conductivity testing equipment calorific value testing machine |
![]() |
Fire Lab Astm E84 Steiner Tunnel Test For Building Materials |
![]() |
Lab Fire Testing Machine Astme E84 Steiner Tunnel For Building Material Lab Testing Equipment |
![]() |
IEC61215 IEC61646 UL1703 Impact Test Equipment |
![]() |
Test Instrument Fire Resistance Testing Of Roof Covering Materials Test Machine UL790 |
![]() |
380V 50HZ Power Supply Fire Test Equipment For Building Materials UL790 Standard |
![]() |
Fire Propagation Index Testing Equipment For Building Materials And Structures |