China Hematology Analyzer Reagent manufacturer
Dewei Medical Equipment Co., Ltd
Work for Human Health! Best service to you by the outstanding R&D and cost-effective products.
9
Home > Products > Rapid Test Kit >

CE Vibrio Cholerae Rapid Test Kit O1/O139 Stool Detection Qualitative Rapid Test

CE Vibrio Cholerae Rapid Test Kit O1/O139 Stool Detection Qualitative Rapid Test

Brand Name Dewei
Model Number VCO-DS02
Certification CE, ISO
Place of Origin Guangdong, China
Minimum Order Quantity 3000
Price Negotiable
Payment Terms T/T, Western Union, MoneyGram, Paypal
Supply Ability 50000 tests per day
Delivery Time 12-30 working days
Packaging Details 25 tests per box, 625 tests per carton
Parameter Vibrio Cholerae Rapid Test
Test Type Qualitative Detection
Method Rapid Visual Immunoassay
Sample Feces/Stool
Result Time 15 minutes
Storage 2-30℃
Usage Professional ivd use only
Test Antigen Test
Detailed Product Description
Vibrio Cholerae O1/O139 Rapid Test
Intended Use

The Vibrio cholerae Rapid Test is a rapid visual immunoassay for the qualitative, presumptive detection of Vibrio cholerae O1 and/or O139 in human fecal specimens. This kit is intended for use as an aid in the diagnosis of Vibrio cholerae O1 and/or O139 infection.

 

Principle


The Vibrio cholerae O1/O139 Antigen Rapid Test detects Vibrio cholerae O1/O139 through visual interpretation of color development on the internal strip. The test contain two strip in cassette, in each strip, anti- Vibrio cholerae O1/O139 antibodies are immobilized on the test region of the membrane. During testing, the specimen reacts with anti- Vibrio cholerae O1/O139 antibodies conjugated to colored particles and precoated onto the conjugate pad of the test. The mixture then migrates through the membrane by capillary action and interacts with reagents on the membrane. If there is sufficient Vibrio cholerae O1/O139 in the specimen, a colored band will form at the test region of the membrane. The presence of this colored band indicates a positive result, while its absence indicates a negative result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

 

Product NameVibrio Cholerae O1/O139 Antigen Rapid Test
BrandDewei
OriginChina
ContentsRapid Test+Specimens Dilution Tube with Buffer+Insert
SpecimenFeces
FeaturesSimple; Accurate; Affordable
TestQualitative Detection
ManufacturerDewei Medical Equipment Co., Ltd

 

Operation


Bring tests, specimens, buffer and/or controlstoroomtemperature (15-30°C) before use.

1. Specimen collection and pre-treatment:

1) Best results will be obtained if the assay is performed within 6 hours after collection.

2) Unscrew and remove the dilution tube applicator stick.

3) Place the applicator stick back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube.

4) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer.

2. Testing:

1) Remove the test from its sealed pouch, andplaceitona clean, level surface. Label the test withpatientorcontrol identification. To obtain a best result, theassayshould be performed within one hour.

2) Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 2 drops of solution into the specimen well (S) of the test cassette.

Avoid trapping air bubbles in the specimen well(S), and do not drop any solution in observation window.

As the test begins to work, you will see color move across the membrane.

3) Wait for the colored band(s) to appear. The result should be read in 15 minutes.

3. Reading results:

Product Images


 

For further operation or performance details, please refer to final instruction manual.

Product Tags: vibrio cholerae rapid test kit   vibrio cholerae Qualitative Rapid Test   Stool Detection Qualitative Rapid Test  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Dewei Medical Equipment Co., Ltd
Subject:
Message:
Characters Remaining: (80/3000)