Hematology ABX Reagents Horiba 5 Part Diluent Lyse Clean Pentra 60
|
|
FDA CE CFDA Certificate Hematology ABX Reagents Horiba 5 Part Diluent Lyse Clean Pentra 60 Intended Use of Pentra reagents To be used for blood cell counting, sizing, and WBC
differentiation, hemoglobin determination on ABX ( Horiba ) Pentra
60 Hematology Analyzers. Specification
Limitations of Detection Method If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details. Storage The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.
Attention 1. This product is an in vitro diagnostic reagent; 2. Pay attention to seal and prevent pollution; 3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity; 4. If the product freezes, it should be completely defrosted at room temperature and used after mixing. 5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations; 6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.
Some product questions you may want to ask:
2) What is the diluent in the hematology analyzer?
3) What is the use of Lyse in hematology analyzer?
4) Can send CBC reagent samples by customer's request? Of course, our company is preparing some sample for those large consumption currently.
5) Except Hematology Reagents, what else can manufacturer offer? Virus Transport Medium (Room Temperature) Sample Release Kit (Sample Collection in 5 Seconds, Directly Use on
PCR) 6) Can diluent, lyse or cleaner from different manufacturers or different batches mixing used? In principle, different brands of diluent and hemolytic can not mix, because the composition and concentration of the reagents are different. The mixture may use lead to inaccurate results.The washing solution is not very different in principle, but because we haven't done the related experiment, we can only tell the customers that it can't be mixed, and the use may affect the cleaning effect and the bottom result.
|
||||||||||||||||||||||||
| Product Tags: clinical diagnostic reagents abx chemicals | ||||||||||||||||||||||||
|
ABX Reagents Horiba 3 Diff MICROS 60 / 45 Cell Counter |
|
Hematology ABX Horiba Analyzer Reagents Horiba 5 Part Pentra 60 80 120 |
|
ABX Horiba Hematology Analyzer Chemistry Analyzer Reagents In Vitro Diagnostic Pentra 120 5 Part |
|
Hematology ABX Reagents Horiba 5 Part Diluent Lyse Clean Pentra 60 80 120 Cell Counter |
|
Disposable ABX Reagents Micros 60 Reagents Diluent 20L Compatible on Horiba CBC Analyzer |
|
Blood Cell Counting Horiba ABX Reagents Diluent / Lyse / Rinse Micros Pentra Series Hematology |