China Instrument Current Transformer manufacturer
Shenzhen Chuangyin Co., Ltd.
Shenzhen Chuangyin Co., Ltd. We are manufacturer. We will take high-quality service and high-quality products to satisfy you. We have advanced management experience, production flow and quality
9
Home > Products > MV Voltage Transformer >

MV Voltage Transformer DZX10-12R Voltage Transformer (with fuse) 12Kv Indoor Single-Phanse Epoxy Resin Type Indoor Use

MV Voltage Transformer DZX10-12R Voltage Transformer (with fuse) 12Kv Indoor Single-Phanse Epoxy Resin Type Indoor Use

Brand Name CY-Group
Model Number JDZX10-12R
Certification KEMA CE ISO SGS TUV UC3
Place of Origin China
Minimum Order Quantity 1pcs
Price NEGOTIABLE
Payment Terms L/C, TT,D/A,D/P
Supply Ability 3600000pcs/year
Delivery Time 3-8 days
Packaging Details Plymood
Material Epoxy Resin
Voltage 15/24KV
Rated Frequency 50/60Hz
Installation site Indoor
Rated primary voltage (kV) 3 6 10
Rated secondary voltage 0.1 0.1/0.1 0.1/0.22
Standard IEC60044-2:2003
Burden power factor cos¢=0.8(lagging)
Rated insulation level(kV) 12/28/75
Accuracy 0.2 0.5 1 0.2/0.2 0.5/6P
Detailed Product Description

MV Voltage Transformer DZX10-12R Voltage Transformer (with fuse) 12Kv Indoor Single-Phanse Epoxy Resin Type Indoor Use

 

JDZX10-12R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor for measuring current, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 7.2/12kV

The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation and maintenance free etc.

 

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs..

 

Technical Data

  1. Installation Site: indoor
  2. Rated Frequency: 50/60Hz
  3. Load power factor cosΦ=0.8 (lagging)
  4. Technical standard accords with GB1207-2006 / IEC 60044-2:2003

 

Technical Data

1. Rated Frequency : 50/60Hz

2. Load power factor cosΦ=0.8 (lagging)

3. Technical standard accords with IEC60044-2:2003 instrument transformers—Part 2: Inductive voltage transformers.

 

Type

Rated primary

Voltage

(kV)

Rated secondary

Voltage

(kV)

Accuracy classes

combination

Rated output (VA)

Thermal limiting

Output

(VA)

Rated

Insulation level

(kV)

JDZX10-3R

JDZX10-6R JDZX10-12R

3

6

10

0.10.22540012/28/75
0.550
180
0.1/0.10.2/0.210/10200
0.2/0.515/30
0.1/0.220.2/6P15/500500
0.5/6P30/500

 

Outline drawing

African Supplier

Product Tags: medium voltage transformer   medium voltage potential transformer  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen Chuangyin Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)