China Instrument Current Transformer manufacturer
Shenzhen Chuangyin Co., Ltd.
Shenzhen Chuangyin Co., Ltd. We are manufacturer. We will take high-quality service and high-quality products to satisfy you. We have advanced management experience, production flow and quality
9
Home > Products > MV Voltage Transformer >

JSZV20-12R MV Voltage Transformer 12kV VT IEEE BUSHING TYPE Resistance Contamination

JSZV20-12R MV Voltage Transformer 12kV VT IEEE BUSHING TYPE Resistance Contamination

Brand Name Chuangyin
Model Number JSZV20-12R
Certification Kema,CE,SGS,TUV
Place of Origin Shenzhen
Minimum Order Quantity 1set
Price negotiable
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 36,000,00pcs per year
Packaging Details Carton packing for one sets, one set including three piece with Components
Net Weight 57KG/pcs
Insulation Site Indoor
Feature High Reliability, Low Magnetism of Core
Construction Full-enclosed
Package 1pcs/Plywood=445*440*440mm
Um 12KV
Detailed Product Description

JSZV20-12R MV Voltage Transformer 12kV VT IEEE BUSHING TYPE Resistance Contamination


1.Product Introduction:
 

 

Voltage transformer with fully enclosed cast insulation structure, the primary and secondary windings and toroidal core all encapsulated in epoxy casting body, using elbow-type plug to increase the outer insulation creepage distance and resistance contamination and moisture performance. It is used indoor for measuring voltage, electric energy and protective relaying in three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12M
The primary cone accords with IEEE 386-2006 figure 7.

 

Technical Data

 

1. Installation site: Indoor
2. Rated frequency: 50/60Hz
3. Load power factor: coscD=0.8 (lagging)
4. Technical standard accords with: IEC 60044-2
                                                         IEC 61869-1 &3

Specification:

 

ItemSpecificationUnitData
1UmkV12
2Rated Insulation LevelkV12/28/75
3Rated Primary VoltageV11000
4Rated Secondary VoltageV110 or 220
 

 

Type

Rated primary

voltage (kV)

Rated secondary voltage (kV)Accuracy classes combination

Rated output

(VA)

Thermal limiting current

(VA)

Rated insulation level(kV)
JSZV20-12R11

 

0.11

0.22550012/28/75
0.550
180

 

0.11/0.11

0.2/0.210/10400/400
0.2/0.510/20

 

0.11/0.22

0.2/6P(3P)20/800300/800
0.5/6P(3P)50/800

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Outline drawing

 
 
 
 
 
 
 
 
 