Detected circuit board | SMT solder paste printed circuit board inspection |
Detection method | Bidirectional structure light projection phase measurement
profilometry |
camera | 4M pixel high speed camera |
Resolution / Vision Range / Speed | 15μm/Pixel FOV : 30.72mm×30.72mm Detection speed <330ms/FOV |
Minimum pad size | 0.125mm*0.125mm |
The largest pad size | 10mm*10mm |
Maximum measurement height | 1000mm |
Minimum pad spacing | 0.1mm |
PCB color effect | no effect |
Programming mode | Import Gerber (274X, 274D) files for automatic programming; |
remote control | In the LAN, remote operation via TCP / IP network, viewing,
starting or stopping the operation of the machine, modify the
program and other operations; |
Detection coverage type | Volume, area, height, offset, tin, tin, tin, tin tip, pollution,
etc.; |
Volume repeatability | <1% at 3σ (correction module) |
High accuracy | 1.5um (correction module) |
GR&R | <10% at 6σ(tolerance=±50%) |
Special features | Supports automatic call-up and multi-board multi-program detection. |
Bar code system | Automatic barcode recognition (1D or 2D code) |
Server mode | With the central data server, several SPI data can be centrally
managed. |
operating system | Windows 7 Professional Edition. |
System Specifications | |
PCB size range | 50×50mm(Min)~450×450mm(Max)(The segment detection technology
supports up to 1300mm) |
PCB thickness range | 0.3 to 6 mm |
The maximum PCB weight | 3KG |
PCB curvature | <5mm |
Clear height above and below PCB | Top Side: 30 mm PCB Bottom Side: 70mm |
Conveyor system | Automatic splint, automatic entry and exit plate, flat belt,
automatic width adjustment |
Conveyor height above ground | 890 to980mm |
Conveyor flow | It can be set as Left→Right→Right two-section track by button |
X/Y platform driver | Screw and AC servo motor drive; PCB fixed, Camera moves in XY
direction, each one is CTQ certified |
power supply | AC230V 50/60 Hz is less than 1.5KVA |
Pressure | 0.4~0.8Mpa |
Before and after device communication | Smema |
equipment weight | About 850KG |
Equipment dimensions | 900 × 1300 × 1565mm (L × W × H) does not include the height of the
signal lamp |
Environmental temperature and humidity | 10 to 35°C 35 to 80% RH (without condensation) |
Equipment safety regulations | Comply with CE safety standards |
Optional items | SPC repair station; off-line programming; external barcode
identifier; track lengthened (free-standing) |