China Transit Time Ultrasonic Flow Meter manufacturer
Lanry Instruments (Shanghai) Co., Ltd.
Lanry Instruments (Shanghai) Co., Ltd. Specialize In Ultrasonic Flowmeter More Than 20 Years!
7
Home > Products > Portable Ultrasonic Flow Meter >

Clamp On Portable Ultrasonic Flow meter Liquid Measure

Clamp On Portable Ultrasonic Flow meter Liquid Measure

Brand Name Lanry
Model Number TF1100-EP
Certification ISO9000, CE, CPA,CMC
Place of Origin China
Minimum Order Quantity 1PC
Price Negotiable
Payment Terms T/T
Supply Ability 1000pcs/month
Delivery Time 7-10 working days
Packaging Details carton packing 44X33X22cm 1PC/carton
Measure principle transit-time difference
Veolicty range 0.01 to 12m/s
Accuracy Reading+/- 1%
Pipe size DN20-6000
Transducer Clamp-on; non-invasive
Output datalogger/4-20mA /OCT /RS485/RS232/GPRS
Detailed Product Description

 

The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

 

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

 

Features:

1.50-hour battery (rechargeable), back-lit 4 lines display all integrated into a rugged, watertight enclosure.

2. Data logger function.

3. The heat measurement function by configuring with paired temperature sensors.

4. Non-invasive transducers.

5. Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

6. Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

7. Lightweight and easily transportable in box.

 

Applications:

General

 Service and maintenance

 Replacement of defective devices

 Support of commissioning process and installation

 Performance and efficiency measurement

- Evaluation and assessments

- Capacity measurement of pumps

- Monitoring of regulating valves

 

 Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)

Petrochemical industry

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc

Refrigeration and air conditioning systems

Food , beverage and pharmaceutical industry

Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc

Metallurgy and mining applications

Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 

 

Specifications: Transmitter

 

Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V Up to 50 h with fully charged internal batteries
Enclosure typePortable
Degree of protectionIP65
Operating temperature-20℃ to +60℃
Housing materialABS( UL 94HB)
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA,OCT, Relay, RS232, RS485 (Modbus),Logged data
SecurityKeypad lockout, system lockout
Size270X215X175mm
Weight3kgs

 

Specifications: Transducer

 

Degree of protectionIP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid TemperatureStd. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer SizeType S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*32(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducerAluminum for standard temp. sensor,and peek for high temp. sensor
Cable LengthStd:5m
Temperature SensorPt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

Product Tags: portable ultrasonic water flow meter   portable ultrasonic liquid flow meter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Lanry Instruments (Shanghai) Co., Ltd.
Subject:
Message: