Introduction: Transformer Capacity Testing Equipment is designed for transformer capacity, load loss and no load loss
testing, it can measure following parameters of transformer:
capacity, transformer type, no-load current, no-load loss, short
circuit (load) loss and impedance voltage. Transformer Capacity Testing Equipment is reliable, accurate, simple for wiring and operation. Features: Measurement range of voltage, current and capacity is wide, and
measurement range can convert automatically. For example, the
instrument can complete load test under full current of
distribution transformer below 1000kVA. The load test of
distribution transformers below 3150kV can be completed under 1/3
of the rated current (under 1/3 rated current, the instrument can
be converted to the load loss parameter under the rated current). When testing load and no load loss of three phase transformer, Transformer Capacity Testing Equipment can automatically determine whether the wiring is correct or not,
and display vector of three phase voltage and current. All test results can be automatically corrected by Transformer Capacity Testing Equipment. LCD 20 * 240 large screen. Users can preset 40 sets sample parameters, and these parameters
can be deleted or added at any time. With real-time electronic clock, which can automatically record
test date and time. 500 sets test data can be stored in the tester, meanwhile, users
can connect the tester with computer to upload the data. Transformer Capacity Testing Equipment has built-in printer, users can print test result immediately after
test. Allows external current transformers or voltage transformers to
extend measurement range, so it can test any kinds of transformers.
Specifications: 1 | Test Parameters | Transformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss | 2 | Working power | Input voltage | 185Vac~250Vac | Allowable input voltage | 85Vac~264Vac | Frequency | 50/60Hz | Allowable frequency | 45Hz~65Hz | Input power | 40VA | 3 | AC voltage | Range | 10~650V | Resolution | 0.001V | Accuracy | 0.2%±0.001V | 4 | AC Current | Range | 0.5~60A | Resolution | 0.001A | Accuracy | 0.2%±0.001A | 5 | Frequency | Range | 45Hz~65Hz | Resolution | 0.001Hz | Accuracy | 0.2%±0.001Hz | 6 | Power | Range | 0~39kW | Resolution | 0.001kW | Accuracy | <±0.5%(CosΦ>0.1) ±1.0%(0.02<CosΦ<0.1) | 7 | Capacity test range | 10kV Dry type transformer | 30kVA~3150kVA | 10kV Oil immersed transformer | 30kVA~3150kVA | 35kV Oil immersed transformer | 50kVA~31500kVA | 20kV Dry type transformer | 50kVA~2500kVA | 35kV Dry type transformer | 50kVA~2000kVA | 8 | Environment | Operating temperature | -10℃~+50℃ | Storage temperature | -25℃~+70℃ | Relative humidity | 5%~95% | 9 | Dimension | 40cm*30cm*22cm | 10 | Weight | ≈8kg (Excluding accessories) |
|