China Laboratory Test Equipment manufacturer
Advanced Instruments Co.,Limited
6
Home > Products > Electrical Test Instrument >

CT PT Analyzer For Automatic CT PT Analysis with Large Touch Screen

CT PT Analyzer For Automatic CT PT Analysis with Large Touch Screen

Brand Name AI
Model Number CPT-I
Certification ISO9001
Place of Origin China
Minimum Order Quantity 1 set CT PT Analyzer
Price Negotiable
Payment Terms Western Union, T/T, L/C, MoneyGram
Supply Ability 100 sets each month
Delivery Time 15 days
Packaging Details CT PT Analyzer packed in veneer case, about 20kg
Applicable transformer Current transformer, voltage transformer, CT, PT, VT
Test Standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Knee voltage 45kV
Voltage Output 0.1~180V
Current Output 0.001~5A(RMS)
Display Large LCD screen display
Size 485mm×356mm×183mm
Weight <15kg
Warranty 1 yearr
Color Black
Detailed Product Description

Introduction:

CPT-I CT PT Analyzer is used to measure all kinds of current transformer and voltage transformer.

CPT-I CT PT Analyzer can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test.

CPT-I CT PT Analyzer can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

 

 

Application:

Tests for current transformerTests for voltage transformerApplications for CT PT analyzer
Excitation curve and parameters testTurns ratio testCT nameplate check
Turns ratio testPolarity testCT parameters check in work burden
Ratio and phase error testSecondary burden testCT transient parameters analysis
Polarity mark checkCoil resistance testCT ratio and phase error calibration
Coil resistance measurementRatio error, phase angle error testPT routine test
Secondary loop burden measurement  
Error line curve test for protection CT  
Transient CT parameters test  
CT nameplate guess  
Saturation hysteresis loop curve measurement  
 

 

Features:

  1. Make evaluation for test results according to selected standards.
  2. The CPT-I CT PT Analyzer can give word report for test result.
  3. Make word reports one time for multi-group test records on the PC.
  4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
  5. Compare excitation curves with saved excitation curves in the same window.

 

Specifications:

  • Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
  • Power supply: AC220V±10%, 50/60Hz±10%
  • Voltage output: 0.1~180V (AC)
  • Current output: 0.001~5A(RMS)
  • Power output: 500VA
  • Maximum knee voltage measurement: 45KV
  • PT ratio error measurement: typical error <0.05%, maximum error<0.1%
  • PT phase angle measurement: maximum error < 3min
  • Memory capacity: >1000 groups test results
  • Working condition: temperature: -10℃~50℃, humidty: ≤90%
  • Size: 485mm×356mm×183mm, weight: <15kg

Product Tags: CT PT Analyzer   CT Analyzer   PT Analyzer  