The resulting test chamber is insulated with calcium silicate
insulation board and is provided with a temperature resistant
observation window.
The stainless steel sample support assembly is mounted on a sliding
platform to allow safe and easy loading of the test sample.
The radiant heat is applied by means of a gas-fuelled panel,
inclined at 30º, and directed at a horizontally mounted floor
covering system specimen.
The radiant panel generates a radiant energy flux distribution
ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1
kW/m2.
Dummy calibration specimen with holder, calibrated heat flux meter
and mounting on the Flooring Radiant Panel Tester .
The distance burned until flame-out is reached and converted, by
calibration, into an equivalent critical radiant flux, in kW/m2.
Heat Flux Meter: Range 0 ~ 50 kw/m2; Surface emissivity: ε=0.95±
0.05
A smoke measuring system, according to DIN 50055, is mounted on a
separate frame at the exhaust stack.
Control Rack for convenience in use, allowing observation of the
apparatus and controls during equipment set-up and calibration.
Automatic ignition of the radiant panel and safety cut-out.
Automatic moving T type ignition burner is supplied with Flooring Radiant Panel Tester .
Stainless steel hood with smoke measurement ports.