China Laboratory Test Equipment manufacturer
Advanced Instruments Co.,Limited
6
Home > Products > Electrical Test Instrument >

Automatic Transformer Tangent Delta Power Factor Tester Electrical Instrument

Automatic Transformer Tangent Delta Power Factor Tester Electrical Instrument

Brand Name AI
Model Number TDT
Certification ISO
Place of Origin China
Minimum Order Quantity 1 Set Power Factor Tester
Price Negotiable
Payment Terms T/T, Western Union, L/C
Supply Ability 100 sets per month
Delivery Time 15 days
Packaging Details Transformer Tangent packed in Plywood case
Power supply AC 220V±10%
Display LCD
Keyword Tangent Delta Analyzer,Power Factor Tester
High output 0.5KV~10KV
Maximum current 200mA
Capacity 2000VA
Size 350*270*270mm
Weight 28KG
Detailed Product Description

 

Capacitance Tangent Delta Power Factor Dielectric Loss Tester

 

 

I.Introduction:

Tangent delta tester is a high-precision instrument, which can be applied to automatically measure electrical loss tangent ( ) and capacitance of all kinds of high voltage electrical equipments on the spot of power plants, substations,laboratory, etc. The instrument is an integrated structure with a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor.

 

II.Features:

★Large LCD display

Simple operation, the instrument is equipped with a high-end full touch LCD screen, super touch interface, and each process is very clear. Operators can use it without additional professional training.

★Mass storage data

The instrument is equipped with a calendar chip and large capacity memory. The test results can be stored in chronological order. Users can view historical data at any time and print it out.

★Multiple test modes

The instrument can be tested by high pressure, high voltage, standard, positive connection method, reverse connection method, self excitation method and other methods.

★CVT test step in place

The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test.

★Do not dismantle the high-voltage lead measurement CVT

The instrument can accurately measure the dielectric loss and capacitance of CVT without dismantling the CVT high voltage lead.

★CVT reverse shield method for measuring C0

The instrument can be used to measure the dielectric loss and capacitance value of C0 on the upper end of CVT.

★High speed sampling signal

The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.

★Multi protection security

The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature.


II.Specifications:

 

1Use conditions-15℃∽40℃RH<80%
2Anti-interferenceFrequency conversion
3PowerAC 220V±10%Allowable generator
4High output0.5KV∽10KV(rated voltage:10KV)Every 0.1kV
0.5KV∽12KV(rated voltage:12KV)
Precision2%
Maximum current200mA (rated voltage:10KV)
167mA (rated voltage:12KV)
Capacity2000VA
5Self-excited powerAC 0V∽50V/15A45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6Resolving powertgδ: 0.001%Cx: 0.001pF
7Precision△tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8measuring rangetgδUnlimited
C x15pF < Cx < 300nF
rated voltage:10KV10KVCx < 60 nF
5KVCx < 150 nF
1KVCx < 300 nF
rated voltage:12KV12KVCx < 30 nF
5KVCx < 150 nF
1KVCx < 300 nF
CVT testCx < 300 nF
9CVT range10∽10000
accuracy0.1%
Resolving power0.01
10Exterior dimension350(L)×270(W)×270(H)
11Memory sizeThe 200 groups supports U disk data storage
12Weight28 Kg
Product Tags: Transformer Tangent Delta Tester   Transformer Power Factor Tester   Power Factor Tester  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Advanced Instruments Co.,Limited
Subject:
Message:
Characters Remaining: (80/3000)