China Laboratory Test Equipment manufacturer
Advanced Instruments Co.,Limited
6
Home > Products > Electrical Test Instrument >

Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

Brand Name AI
Model Number DFT
Certification ISO
Place of Origin China
Minimum Order Quantity 1 Set Transformer Oil Volume Resistivity Meter
Price Negotiable
Payment Terms T/T, Western Union, L/C
Supply Ability 1000 sets per month
Delivery Time 15 days
Packaging Details Transformer Oil Volume Resistivity Meter packed in Plywood case
Power supply AC 220V±10%
Display LCD
Keyword Dissipation Factor Tester,Volume Resistivity Meter
AC HV output 400V-2200V
DC HV Output 200V-600V
Warranty 1 Year
Size 450(L)×310(W)×360(H)
Weight 21KG
Detailed Product Description

 

Insulation Oil Dielectric Dissipation Factor Volume Resistivity Tester

 

I. Introduction:

Automatic Dielectric Dissipation Factor Tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.

This oil tan delta analyzer is integrated with oil cup for dielectric loss, temperature-control equipment,temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor,high resistance meter and DC high-voltage power etc.
The most advanced heating mode of high frequency induction is applied to the heating part of this iinsulation oil dissipation factor tester, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the transformer oil volumn resistivity tester can operate correctly.
The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and capacitance is not influenced by environmental temperature and dampness etc. In this way, the accuracy of insulation oil dielectric loss tester is guaranteed conformably after a long-time application.

 

 

II. Specifications:

Condition of Use-5℃-40℃ RH<80%
Power SourceAC 220V±10% Without Frequency Limit
AC High Voltage Output400V-2200V ±2% Every 100V 50VA
DC High Voltage Output200V-600V ±2%
Temperature Control Induction StoveMaximal Power 500W
Temperature Control Range<100℃
Temperature Measuring Error±0.5℃
Control Temperature Error0.1℃
Control Temperature TimeRoom Temperature 90℃ <20min

Measuring Range

tgδ Without Limit

Cx 15PF-300PF

Rx 10M-10T

Resolution

tgδ 0.001%

Cx 0.01pF

Rx 0.01

Precision

delta tgδ:±(Reading*0.5%+0.020%)

delta Cx :±(Reading*0.5%+0.5PF)

delta Rx :±Reading * 10%

Relative Dielectric Loss ConstantΕr Calculated Automatically
Volume Resistivityρ Calculated Automatically
Dimension450(L)×310(W)×360(H)
Net Weight21KG
 

 

 

Oil Cup of Dielectric Dissipation Factor Volume Resistivity Meter

 

Product Tags: Volume Resistivity Meter   Oil Volume Resistivity Meter   Transformer Oil Dissipation Factor Test Set  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Advanced Instruments Co.,Limited
Subject:
Message:
Characters Remaining: (80/3000)