Introduction
FZG gear wear test machine is a multi-purpose testing machine.It can be used for the evaluation of the scuffing load capacity of
the lubricant, also can be customized according to client’s demands. It is usually using for gear bending fatigue strength and gear touch
fatigue strength test.
This FZG scuffing load capacity testing equipment confirms to GB/T
13672-92 standard test method for scuffing load capacity of
gears,ASTM D5182 Standard Test Method for Evaluating the Scuffing Load Capacity of
Oils (FZG Visual Method), and SH/T 0366-1992 lubricant carrying capacity test method (CL-100
Gear machine method)
Technical specification:
1 | Max. torque | 1Kn. m |
2 | Max. loading class | 13 |
3 | Temperature control accuracy | ±2℃ |
4 | Motor power | 6.5/8kw |
5 | Motor speed | 1450/2880 r/min |
6 | Gear box volume | 1.25L |
7 | Heating power | 0.5X3=1.5kw |
8 | Dimensions | 1390X750X1082mm |
Working conditions
1.The fluctuation range of the power supply voltage should not exceed
the rated value ± 10% and the fluctuation range of the frequency
should not exceed 2% of the rated value.
2.Test FZG test equipment should be installed horizontally and the
installed base should be smoothly. The horizontal error for the
host workbench aspect direction should not exceed 0.2/1000.
3.Room temperature 10 º C-35 º C.
4.The environment no vibration, no strong magnetic interference and
non-corrosive media.
5>Relative humidity less than 80%.
Structural characteristics and working principle
1. Loading mode
This FZG scuffing loading capacity test equipment is a dynamic
closed-loop configuration, and load mode adopts rod hanging weights
mode.
The loading lever is hung on the load sheave clutch. By hanging
weights plus through fastening loaded clutch nut and make the two
sheave tighten which installed on the loaded clutch. Then remove
the weights and the loading lever and you can readout the torque on
the clutch torque measurement.
2. Installation and adjustment
Make the test machine at the level of the floor and mat three
horns. Put the spirit level on the test table. By adjusting the
horn to make the vertical and horizontal direction error do not
exceed 0.2/1000.
The fzg test machine host should be placed separately from the
control cabinet to avoid the noise and pungent odor when the
testing machine working. After the start of the test machine,
person can not inter into the room which the machine placed.
The test procedure in accordance with the the "lubricant carrying
capacity assay (CL-100 gear machine method) SH/T0306-92"
provisions.