China Laboratory Test Equipment manufacturer
Advanced Instruments Co.,Limited
6
Home > Products > Oil Test Equipment >

4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets

4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets

Brand Name AI
Model Number 4530F
Certification ISO
Place of Origin China
Minimum Order Quantity 1 set 4530F Atomic Absorption Spectrophotometer
Price Negotiable
Payment Terms L/C, T/T, Western Union
Supply Ability 200 sets per month
Delivery Time 20 days
Packaging Details 4530F Atomic Absorption Spectrophotometer packed in Plywood case
Test method Atomic Absorption Spectrometry AAS
Wavelength Range 190 ~ 900nm
Wavelength Accuracy ±0.15nm
Lamp Turrets 8 PCS
Spectrum Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm
Operation PC controlled
Power supply AC220V±10%/50HZ
Warranty 1 Year
Detailed Product Description
 
4530F PC Controlled Flame Graphite Furnace Atomic Absorption Spectrophotometer
 

Features:
This AAS machine is complete automatic controlling system;
The AA spectrophotometer can be worked with advanced graphite furnace temperature controlling technology;
Safe, reliable and convenient flame system;
Multi-functional software workstation;
This flame system atomic absorption spectrophotometer is ompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
Fully automated wavelength scanning and peak searching;
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
Deuterium lamp and self-absorption background regulation;
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
Measuring method of AAS machine: flame absorption method and emission method;
Result printing: parameter printing, data result printing and diagram printing;

 

Instrument Configuration:

Atomic Absorption Spectrophotometer 1pc
Air compressor without noise 1pc
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

 

Specifications:

Wavelength range190 ~ 900nm
Spectral bandwidthCan automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength±0.15nm
Receptivity of the wavelength≤0.04nm
Base line stability≤0.002A/30min (Cu)
Characteristic viscosity0.02μg/ml/1% (Cu)
Checking limit0.004μg/ml (Cu)
Preciseness0.5%
Grating1800 lines/mm
InflamerAll-metal titanium burner
AtomizerEffective glass atomizer
Lamp standEight lamps
D2 background correction abilityWhen the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight700mm×550mm×450mm 75Kg
Power source220V±22V AC

 


Flame System:

Acetylene air burner100mm
Nitrous oxide acetylene flame head50mm
Ignition dynamic baseline drift≤0.006A/30min
(Cu) Characteristic viscosity≤0.025μg/ml/1%
Related standard deviation of the accuracy≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety systemCan automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner

 


Graphite Furnace:

The highest temperature3000℃
The largest temperature rising speed≥2000℃/S
Characteristic quantityCd≤0.5×10-12g Cu≤0.5×10-11g
AccuracyCu≤3% Cd≤3%
Size and weight550mm×450mm×300mm 65Kg
Safety systemOver current protection
ProtectionLow air pressure alarm, low cooling water flow alarm
Power source and power220V±22V AC 7000W

 

Product Tags: Atomic Absorption Spectrophotometer   AA Spectrophotometer   4530F Atomic Absorption Spectrophotometer  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Advanced Instruments Co.,Limited
Subject:
Message:
Characters Remaining: (80/3000)