Heat Source : AGF Ribbon Type Propane Gas Burner
Cable Circuit Integrity Fire Resistance Testing Equipment is
equipped with 3 rows of cross holes, Average front width of burner:
15mm, Hole diameter: 1.32mm, Distance between the center: 3.2mm.
A polished hole row in pilot hole for flame preservation in both
faces of Burner plate.
Two thermocouples are horizontally installed separated 45mm left
and right of burner center-line to check temperature.
Mass flow controllers to regulate the gas and air flow, the
accuracy is not less than 1.5%.
Software can show the burner calibration temperature, propane and
air flow rate etc.
The current is provided by a three-phase star transformer with
sufficient capacity to maintain the required test voltage when
circuit integrity cannot be maintained.
Conductor connection indicator (LED indicator) to form a current.
The voltage value is automatically set by software and adjusted by
a panel controller.
Digital display of the current and voltage data, accuracy of
current is 0.001A.
Current protection using fuse with 2A.
The real-time measurement data of all current and voltage are
collected by computer, and the curves of current and voltage are
generated.
When circuit integrity cannot be maintained, the corresponding
indicator lamp is extinguished, the computer automatically
determines the state and records the time, and sends out the sound
and light alarm.