Chemiluminescence Method Trace Nitrogen Content Analyzer as Per ASTM D4629 and ASTM D5762
|
SH708 chemiluminescence nitrogen determination instrument using chemiluminescence method to determine the total nitrogen content, improve the ability of anti-impurity interference, avoid the electric quantity method of titration cell lock operation and thus bring unstable factors, so that the sensitivity of the instrument is greatly improved. The key components of the system are imported, which ensures the performance of the whole machine reliably. Is suitable for the determination of paraffin oil, diesel oil, petrol, fuel oil, lubricating oil, liquefied petroleum gas and natural gas, and other oil products, chemical raw materials and finished product of the total nitrogen content, implement standard SH/T 0657 trace nitrogen in liquid petroleum hydrocarbons assay (oxidation burning and chemiluminescence method, ASTM D4629, GB/T 17674 the determination of nitrogen content in the crude oil boat injection chemiluminescence method. Chemiluminescence Method Trace Nitrogen Content Analyzer as Per ASTM D4629 and ASTM D5762 Ultraviolet Fluorescence Sulfur, Nitrogen-in-Oil Analyzer Ultraviolet Fluorescence Total Sulfur in Light Hydrocarbons Nitrogen-in-Oil Analyzer ASTM D5453 ASTM D5453 Ultraviolet Fluorescence Sulfur,Nitrogen-in-Oil Analyzer Ultraviolet Fluorescence Total Sulfur in Light Hydrocarbons Nitrogen-in-Oil Analyzer ASTM D5453
The performance characteristics of 1, the use of pneumatic support instrument cover, open the instrument cover internal structure at a glance. 2. The front shape and repeatability of low and small content are better. 3, the instrument can be continuously switched on for 24 hours continuous use of accurate chemiluminescence nitrogen determination instrument. 4. The total nitrogen content in the sample was rapidly measured by chemiluminescence method. 5. High-precision data acquisition and the application of computer technology provide a reliable guarantee for data acquisition, control and processing. Technical parameters: Basic parameters: Sample type: liquid, solid and gas Determination method: chemiluminescence method Sample injection volume: solid sample: 1-20mg Liquid Sample: 5-20μl Gas sample: 1-5ml Measuring range: 0.1 ~ 10000mg/L
measurement accuracy:
Temperature control range: room temperature ~ 1050℃ Temperature control accuracy: ±3℃ Gas source requirements: high purity argon: purity above 99.995% High purity oxygen: above 99.995% purity Power source: AC220V±22V, 50Hz±0.5Hz, 1500W Dimensions: Host: 305(W)×460(D)×440(H)mm Temperature control: 550 (W) x 460 x 440 mm (H) (D) Weight: host: 20kg Temperature control: 40 ℃ Complete set of equipment requirements: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operating software, etc. Other options: computer, solid sampler, gas sampler.
Packing list
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Platinum Cobalt Lab Test Instruments ASTM D156 Lab Test Instruments Saybolt Colorimeter Lab Test Instruments |
![]() |
Speed 1250r/Min Liquefied Petroleum Gas Density Meter Heating Power 1000W Power Supply 220V 50HZ |
![]() |
Measuring Range ≥0.001 Mgkoh/G Potentiometer Titration Acid Value Tester Burette Volume 10ml |
![]() |
Bottle Size 200±0.2ml Engler Viscometer For Petroleum Products All-In-One AC220V 50Hz |
![]() |
ASTM D323 Petroleum Testing Instruments SH8017 Gasoline Vapor Pressure Tester Reid Method |
![]() |
ASTM D323 SH8017B Automatic Vapor Pressure Measuring Instrument Fault Self Check |
![]() |
Crude Benzene Distillation Range Tester SH6536 Fully Automatic Boiling Range Tester |