70L FM200 Fire Fighting System For Computer Room Library
|
|
CCC China FM200 Gas Suppression System Cabinet Type Fire Computer
Room Library Cabinet extinguishing equipment don't have to set up a dedicated storage bottle, the whole cabinet put oneself in another's position is set in the protection zone, suitable for computer rooms, archives, valuables such as library, communication machine room space smaller protection zone, a few cabinet device can also be used to protect a large protection zone. When building to set up a dedicated store between bottles, or although there is a store, but the transmission distance is far, can not meet the requirement of the engineering design, or protective zone inconvenient installation system pipe network. Bad protection area clean and tidy, can discharge extinguishing agent will start automatically when you fire extinguishing equipment. Injection time is short, fast extinguishing, the device can be equipped with my company the production of single zone for gas cabinet extinguishing system control panel. Start the way for the automatic control, manual electric control and mechanical emergency manual control three. Automatic control, manual electric control switch can be performed. Manual control should be used in general, in the case of reserve no one can be converted into automatic control. When electric control cannot perform automatic control and manual, mechanical emergency manual control should be adopted.
Never destroy structure of protect area,agent use fully,when there is a fire,it injects gas to the protected area directly,therefore,very effective and fast.No need to do a separate storage room,the device is in protected area,it saves your space, economical and practical.
1.2 system installation Cabinet extinguishing system installation location shall meet the following requirements: (1) the environment temperature 0 ℃ ~ 50 ℃, and a dry, well ventilated; (2) must not contain any explosive, conductive dust in the air and corrosion parts of harmful substances, otherwise must be preserved, device shall not by vibration and impact; (3) the whole cabinet put oneself in another's position must be able to install a smooth, not allowed to tilt; (4) when fire protective zone should be kept closed condition, other than the pressure mouth opening, and for the protection of the ventilator and fire damper in the ventilation pipe, the discharge of seven fluorin propane before, should be close; (5) when equipped with outside elastic door closers or clicks, if its open mouth area of not less than the pressure calculation area, not the set pressure. (6) is installed in the position in the protective zone should be chosen to avoid close to the heat source and direct sunlight exposure, and close to the wall installation. Nozzle jet direction should be toward the protection zones. When the system installation, should be conducted in accordance with the following order: place the cabinet put oneself in another's position specified in the protected area. Extinguisher bottle group to be included in the cabinet put oneself in another's position, the position and centered between the into can not produce too big impact, shall not make bottle group of dumping. With coupling nut connecting piping components and bottle container valve outlet, pay attention to the container valve outlet connections need to coupling nut screw onto a tube (the left-hand thread) on the road, screwing in depth for connecting pipe sealing circular arc surface and the right end of coupling nut thread bottom basic coincidence, then the right end thread and container valve outlet connections (hand tighten) of seven fluorin propane before, should be close; (5) when equipped with outside elastic door closers or clicks, if its opening area of not less than the pressure release Mouth computing area, and not the other set pressure. Observe whether the nozzle tube and cabinet put oneself in another's position of nozzle hole is, if not is adjustable connecting hoop for, at the same time pay attention to the direction of connecting hoop pressure switch on, must not make the direction of the pressure switch is before or after, regulating and fasten the pipeline in the component. Connect the nozzle tube do auxiliary seal processing (tie ribbons or the sealing glue) and install the nozzle. Fine-tuning extinguisher bottle set position, and make it on the cabinet put oneself in another's position in the back wall and. Installation of hoop and link up with the fixed bottle groups. Wrench tight coupling nut. Install pressure switch do auxiliary seal after processing to the pressure switch seat; And the electromagnetic drive installed on the container valve, locked cupboard door. Installed. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: 70L FM200 Fire Fighting System Library FM200 Fire Fighting System |