IEC 60335-1 Clause 13 Touch Current Measuring Circuit Figure 4
|
|
IEC 60335-1 Clause 13 Touch Current Measuring Circuit Figure 4
Product information: This test network conforms to the measuring network requirements of IEC 60335-1 clause 13, IEC60065:2014 cl.9.1.1.2 b) and Fig.D.1 of Annex D and IEC60990 figure 4-mesuring network, touch current weighted for perception or startle-reaction. This network is convenient for use and easy for operation, and the power supply conversion switch is made separately (refer to IEC 60990 figure 6, it is not included in this device), which can solve the shortcomings of power supply capacity of the previous machine and can test the more powerful products.
Preparation: Before testing, you need to prepare instruments as follow: Oscilloscope x1 One or ten times the voltage probe x1 Power supply x1 (the test voltage or frequency that can be adjusted or changed to the required voltage or frequency)
Test Method
Notice
|
| Product Tags: Current Measuring Circuit Figure 4 IEC 60335-1 Current Measuring Circuit Clause 13 Current Measuring Circuit |
|
UL 964-2000 Mattress Pads Voltage Dielectric Strength Testing Equipment |
|
IEC 60335-2-17 Electric Blanket Withstand Voltage Testing Equipment For Dielectric Strength Test |
|
IEC60335-2-17 Electric Blanket Tumbling Barrel Free Fall Test Apparatus |
|
IEC60335-2-17 Electric Blanket Bending Test Machine 125mm/s |
|
Electric Blanket Heating Wire Flexing Test Apparatus 0.33m/S |
|
Cookware Handle Torque Resistance Test Apparatus TZS 683/2022 Annex B Tester |