China Electrical Appliance Testing Equipment manufacturer
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
7
Home > Products > Environmental Test Chamber >

Explosion-proof Walk-In High and Low Temperature Humidity Test Chamber 8.36m³ 

Explosion-proof Walk-In High and Low Temperature Humidity Test Chamber 8.36m³ 

Brand Name Sinuo
Model Number SN886
Certification Calibration Certificate(Cost Additional )
Place of Origin China
Minimum Order Quantity 1
Price Customized
Payment Terms T/T
Supply Ability 10 sets per month
Delivery Time 30 Days
Packaging Details Plywood Case
Temperature Range -40°C to +120°C
Temperature fluctuation ≤±0.5°C
Temperature deviation ±2.0℃
Temperature uniformity ≤2.0°C
Heating Rate +20°C → +80°C at ≤3°C/min (4 kW load)
Cooling Rate +20°C → -40°C at ≤1°C/min (4 kW load)
Humidity Range 20~98%RH (temperature 20℃~85℃)
Humidity deviation ±3% RH (>75% RH) / ±5% RH (≤75% RH)
Detailed Product Description

 

Explosion-proof Walk-In High and Low Temperature Humidity Test Chamber 8.36m³

 

 

Product information:

 

Compliance standards:

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

(The heat capacity of steel per cubic meter load is not more than 20kg/m3, and no active heat load is applied during wet heat test)

 

Technical Parameter:

 

Temperature range: -40℃~+120℃

Temperature fluctuation: ≤±0.5℃

Temperature deviation: ±2.0℃

Temperature uniformity: ≤2.0℃

Temperature rise time: +20℃→+80℃ ≤3℃/min Load: 4KW battery module

Temperature drop time: +20℃→-40℃ ≤1℃/min Load: 4KW battery module

Humidity range: 20~98%RH (temperature 20℃~85℃) (no active heat load)

 

Relative humidity deviation:  ±3%RH (>75%RH no-load)

                                              ±5%RH (≤75%RH no-load)

Humidity fluctuation: ±2.5%RH

Noise: ≤75dB

 

Structural characteristics:

 

Insulation enclosure structure

Spray-coated galvanized color steel plate--temperature stress resistant insulation material--SUS304 stainless steel plate composite assembly plate.

Among them:

Spray-coated galvanized color steel plate (external) thickness 0.8mm, color is standard warehouse gray.

SUS304 stainless steel plate (inner) thickness 1.0 mm.

The bottom plate uses 2.0mm embossed anti-skid plate.

The thickness of the temperature stress resistant insulation material layer: 100mm.

The load-bearing capacity of the test room floor: 600kg/m2 (uniform load)

Video surveillance
Air conditioning channel

Centrifugal fan: 4 pcs

Heater, evaporator (also dehumidifier), water supply and drainage port, dry bulb temperature sensor.

Wet heat type also includes: humidifier, dry burn preventer, and additional dryer. Guaranteed continuous working time of -10℃~-30℃≥14 days.

Smoke exhaust system

When the smoke alarm is on, the smoke exhaust is turned on, and the maximum air exchange rate is 850m³/h

Fire extinguishing solenoid valve

(1) Smoke sensor:

There is one smoke sensor on each of the upper and lower layers of the temperature chamber. After an abnormal alarm, the power supply of the equipment is cut off and the fire extinguishing device is activated; it is required to be arranged outside the temperature chamber.

(2) After detecting an abnormal signal (the signal threshold and form are defined by Party A and implemented by Party B), spraying is realized in the chamber, without damaging samples and equipment, extinguishing the fire within 30 seconds, and no re-ignition within 30 minutes after power failure;

(3) Fire extinguishing device: Fire water is connected. Spraying fire extinguishing is realized in the chamber.

(4) The fire communication protocol is open. When a fire occurs, the equipment alarm simultaneously feeds back the switch signal to the charging and discharging equipment, and the charging and discharging equipment stops the test through logical judgment.

Manual fire extinguisher switch

Manual fire extinguishing

Explosion-proof port

A set of explosion-proof pressure relief vents is set on the top of the equipment, with a size of 300mm×500mm. When the internal pressure of the box is ≥0.104MPa, the pressure relief vent will open automatically.

Standard configuration of the test chamber

Lead hole: φ100mm 2 (1 on each of the left and right sides of the box)

Lighting: 60W/AC220V 2, three-color light, buzzer

Air pressure balance device

Door

Double hinged door, door opening height 1800 mm, door width 1900 mm.

Equipped with safety door locking mechanism (the door can be opened in the test room).

The door is equipped with 2 electric heating anti-condensation hollow glass observation windows (visible range W400×H600mm), and the door frame is equipped with an anti-condensation electric heating device.

Explosion-proof chain for the main door (8mm)
Control panelTemperature (humidity) control display, over-temperature protection setting device, emergency stop switch, sample terminal USB interface
Machine room

The mechanical room contains:

Refrigeration unit, drainage device, fan, power distribution control cabinet, humidification and moisture measurement water control device

Power distribution control cabinet

Cooling fan

Distribution board

RS-485 physical interface

Main power circuit breaker

Heater

316 stainless steel armored heater

Heater control mode: contactless equicyclic pulse width modulation, SSR (solid state relay)

Humidification (humid heat type only)

Boiler heating and humidification method

316 stainless steel armored humidifier.

Heater control method: contactless equicyclic pulse width modulation, SSR (solid-state relay).

Water level control device, heater anti-dry burning device.

 

Electrical control system:

 

Controller modelPLC
Display7.0”, 800X480 dot matrix TFT color LCD display
Operation modeProgram mode, fixed value mode
Setting methodChinese and English menu, touch input
Program capacityEditable: 100 programs. Each program has a maximum of 100 steps and can be set to 9999 cycles. Programs can be linked
Setting range

Temperature: Adjust according to the temperature operating range of the equipment (upper limit +5°C, lower limit -5°C)

Humidity: 0-100% RH; (humidity equipment)

Display resolution

Temperature 0.01℃; Time 0.01min

Humidity 0.1%RH (humidity equipment)

InputThermal resistor PT100 (platinum resistance/voltage/current, etc., according to equipment requirements)
Communication function (optional)

Can be connected to a computer to display curves and collect data;

Can be used as a monitoring and remote control system;

Can be used to control multiple machines synchronously;

RS-485, RS-232 (optional), Ethernet (optional);

USB2.0 interface.

Control modeTemperature uses anti-integral saturation PID + automatic adjustment function Humidity uses anti-integral saturation PID + automatic adjustment function
Curve recording functionThe battery-protected RAM can save the device's set values, sampling values, and sampling time. The curve recording cycle can be set from 1S to 120 seconds. The maximum memory time is 720 days of continuous storage of historical curves. Historical data (when the sampling time is 2 minutes) can be saved for more than 10 years without continuous use.
Auxiliary functionsFault alarm and cause, processing prompt function; power failure protection function; upper and lower temperature limit protection function; timing function (automatic start and automatic stop operation), self-diagnosis function
Temperature and humidity measurement

Temperature: PT100 thermal resistor

Humidity: electronic humidity sensor

 

 

 

 

 

Product Tags: High Low Temperature Humidity Test Chamber   Explosion-proof Humidity Test Chamber   8.36m³ Humidity Test Chamber  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Sinuo Testing Equipment Co. , Limited
Subject:
Message:
Characters Remaining: (80/3000)