China Electrical Appliance Testing Equipment manufacturer
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
7
Home > Products > Environmental Test Chamber >

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

Brand Name Sinuo
Model Number SN887B-100L
Certification Calibration Certificate(Cost Additional )
Place of Origin China
Minimum Order Quantity 1
Price Customized
Payment Terms T/T
Supply Ability 10 sets per month
Delivery Time 30 Days
Packaging Details Plywood Case
High-Temperature Range +60℃ ~ +180℃
Low-Temperature Range -10℃ ~ -70℃
Temperature Fluctuation ±0.5℃
Temperature Deviation ±2.0℃
Internal Dimensions W500*H500mm*D400mm
External Dimensions W1420mm*H1888mm*D1590mm
Product Volume 100L
Product Weight Approximately 1200kg
Detailed Product Description

 

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

 

 

Product information:

 

This thermal shock test chamber meets the requirements of IEC60068-2-1, IEC60068-2-2, IEC60068-2-30 and IEC60068-2-78, and required by many standards.
It is used to verify whether there is a bad influence on the product due to rapid changes in high and low temperature in such a manner that the sample does not move.

 

Technical parameter:

 

Product NameThermal Shock Test Chamber
Product ModelSN887B-100L
Volume100L
Internal DimensionsW500*H500mm*D400mm
External DimensionsW1420mm*H1888mm*D1590mm
WeightApproximately 1200kg
High-Temperature Range+60℃ ~ +180℃
Heating Time+20℃ ~ +180℃ ≤ 25 min
Note: The heating time refers to the performance when the high-temperature chamber operates independently.
Low-Temperature Range-10℃ ~ -70℃
Cooling Time+20℃ ~ -70℃ ≤ 60 min
Note: The cooling time refers to the performance when the low-temperature chamber operates independently.
Temperature Shock Range-40℃~150℃
Temperature Fluctuation±0.5℃
Temperature Deviation±2.0℃
Temperature Recovery Time≤5min
Temperature Transition Time≤10sec
Recovery Conditions

High-temperature exposure: +85℃ / 30 min → Ambient temperature exposure → Low-temperature exposure: -40℃ / 30 min

Maximum Sample Weight: 20 KG

 

 

Structural Features:

 

Standard Configuration of the Test Chamber

Flush-mounted handle.

Door Hinges: Imported SUS #304 stainless steel hinges.

Shelves: Two SUS #304 stainless steel grille-type shelves, with a maximum load of 20KG per layer.

Adjustable Shelf Tracks: Two sets with 40mm adjustable spacing.

Lead-through Port: One φ50mm port at the top of the chamber.

Chamber Door

Single Door: Opens outward, hinges on the left, handle on the right (when facing the front of the chamber).

Equipped with an observation window (W300 x H450mm) made of anti-fog tempered glass and Philips lighting.

Anti-condensation Heating Device: For window and door frames.

Additional Tempered Glass: Allows clear observation of tests inside the chamber.

Control Panel7-inch display screen, over-temperature protection settings, SD card slot, and RS232 communication interface.
Mechanical RoomRefrigeration unit, compressor water tray, and pressure relief device.
Power Distribution Control CabinetPower distribution board, cooling fan, and main power switch.
Heater

Type: Finned tubular stainless steel electric heater.

Heating Control Method: SSR (Solid State Relay) with zero-crossing

point and periodic pulse width modulation.

Heating Power for Low-Temperature Zone: Approximately 6KW.

Heating Power for High-Temperature Zone: Approximately 9KW.

Power Cable Port and Drain PortLocated at the back of the chamber.
Electrical Controller ModelCustom seven-inch controller.
Operating ModelProgrammable operation / Chinese and English menu, touchscreen input.
Setting Range

High-temperature chamber preheating upper limit: +210℃

Low-temperature chamber pre-cooling lower limit: -80℃

Controller Specifications

Accuracy: Temperature ±0.1℃ + 1 digit

Resolution: Temperature ±0.01℃

Temperature slope: 0.1 ~ 9.9 (adjustable).

Includes upper and lower limit standby and alarm functions.

Temperature input signal: T-type armored thermocouple sensor.

6 sets of P.I.D. control parameters with automatic P.I.D. calculation

 

 

 

Product Tags: IEC60068-2 Thermal Shock Test Chamber   High Performance Thermal Shock Test Chamber   Thermal Shock Test Chamber  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Sinuo Testing Equipment Co. , Limited
Subject:
Message:
Characters Remaining: (80/3000)