IEC 60320-1 Constant Temperature Humidity Climatic Test Chamber Environmental Chamber
|
IEC 60320-1 Constant Temperature Humidity Climatic Test Chamber Environmental Chamber
Product Overview:
This temperature and humidity chamber is required by IEC60335-1 clause 15, etc. This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the products reliability of storage and transportation under high and low temperature alternating heat and humidity. It conforms to standards: IEC60320-1:2021 “Appliances couplers for household and and similar general purposes- Part1: General requirements” clause 14 IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT” IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT” IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT” IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
Structure:
This machine adopts a closed chamber structure with the following features: A. It has an extremely wide temperature and humidity control range to meet the various needs of users. B. It adopts a unique balanced temperature adjustment and humidity control mode to adjust the ideal temperature and humidity environment. The heating and humidification capability are stable and balanced, and the temperature and humidity control are high-precision and high-stability. C. Automatic selection of refrigeration circuit: The automatic control device has the ability of automatically starting the running refrigeration circuit according to the set value of temperature, can start the cooling directly under the high temperature state. The refrigeration adopts the air-cooled condensing unit with fully enclosed compressor (imported). D. The door is equipped with an observation window, which is convenient for observing the test state of the test sample.
Technical Parameters:
Safety Instructions: This test chamber must not be used to test the following substances or containing these substances: 1.1 Explosives 1.1.1 Nitroglycerine (ethylene glycol dinitrate), nitroglycerine (glycerine trinitrate), nitrocellulose and other explosive nitrate esters. 1.1.2 Trinitrobenzene, trinitrotoluene, trinitrophenol (picric acid) and other explosive nitro compounds. 1.1.3 Peroxyacetic acid, methyl ethyl ketone peroxide, benzoyl peroxide and other organic peroxides.
1.2 Combustibles: 1.2.1 Self-igniting items: Metals: lithium, potassium, sodium, yellow phosphorus, phosphorus sulphide, red phosphorus. Celluloid: calcium carbide (calcium carbide), phosphated lime, magnesium powder, aluminium powder, sodium bisulphite. 1.2.2 Oxide properties a. Potassium chlorate, sodium chlorate, ammonium chlorate and other chlorates. b. Potassium peroxide, sodium peroxide, ammonium peroxide and other peroxylates. c. Potassium peroxide, sodium peroxide, barium peroxide and other inorganic peroxides. d. Potassium nitrate, sodium nitrate and other nitrates. e. Potassium hypochlorite and other hypochlorites. f. Sodium chlorite and other chlorites.
1.3 Flammable substances: a. Petrol, acetaldehyde, propylene oxide, carbon disulphide and other substances with a flash point below -30 °C. b. Ordinary ethane, ethylene oxide, benzene, methyl ethyl ketone and other substances with a flash point above -30℃ but below 0℃. c. Methanol, ethanol, xylene, amyl acetate and other substances with a flash point above 0℃ but below 30℃. d. Kerosene, petrol, turpentine, isoamyl alcohol, acid vinegar and other substances with a flash point higher than 30℃ but lower than 65℃.
1.4 Flammable gases: Hydrogen, acetylene, ethylene, methane, ethane, propane, butane and other gases that can burn at 1 atmosphere at 15°C.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Constant Temperature Humidity Climatic Test Chamber IEC 60320-1 Climatic Test Chamber |
![]() |
IEC 60529 IP5X/IP6X 24 CBM Walk-In Sand And Dust Test Room Ground Embedded Type |
![]() |
IEC 60529 IP5X/IP6X Walk-In Sand And Dust Test Chamber 24 CBM For EV Charging Station |
![]() |
IEC 60950 Heating Cabinet for Electronics Safety Testing 225L Temperature RT+10°C ~300°C |
![]() |
Explosion-proof Walk-In High and Low Temperature Humidity Test Chamber 8.36m³ |
![]() |
IEC 60068-2-78 Walk-in Temperature and Humidity Test Chamber 3.38m³ Temp. -40~+100℃ |
![]() |
ISO 4892-1/2 Water-Cooled Xenon Weathering Test Chamber Irradiance Range 0.3W/M2~1.1 W/M2 |