IEC 60068 -40 °C ~ +150 °C Constant Temperature And Humidity Climate Chamber 225L
|
IEC 60068 -40 °C ~ +150 °C Constant Temperature And Humidity Climate Chamber 225L
Equipment Overview:
It conforms to standards: IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT” IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT” IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT” IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
Technical Parameters:
Safety Instructions: This test chamber must not be used to test the following substances or containing these substances: 1.1 Explosives 1.1.1 Nitroglycerine (ethylene glycol dinitrate), nitroglycerine (glycerine trinitrate), nitrocellulose and other explosive nitrate esters. 1.1.2 Trinitrobenzene, trinitrotoluene, trinitrophenol (picric acid) and other explosive nitro compounds. 1.1.3 Peroxyacetic acid, methyl ethyl ketone peroxide, benzoyl peroxide and other organic peroxides.
1.2 Combustibles: 1.2.1 Self-igniting items: Metals: lithium, potassium, sodium, yellow phosphorus, phosphorus sulphide, red phosphorus. Celluloid: calcium carbide (calcium carbide), phosphated lime, magnesium powder, aluminium powder, sodium bisulphite. 1.2.2 Oxide properties a. Potassium chlorate, sodium chlorate, ammonium chlorate and other chlorates. b. Potassium peroxide, sodium peroxide, ammonium peroxide and other peroxylates. c. Potassium peroxide, sodium peroxide, barium peroxide and other inorganic peroxides. d. Potassium nitrate, sodium nitrate and other nitrates. e. Potassium hypochlorite and other hypochlorites. f. Sodium chlorite and other chlorites.
1.3 Flammable substances: a. Petrol, acetaldehyde, propylene oxide, carbon disulphide and other substances with a flash point below -30 °C. b. Ordinary ethane, ethylene oxide, benzene, methyl ethyl ketone and other substances with a flash point above -30℃ but below 0℃. c. Methanol, ethanol, xylene, amyl acetate and other substances with a flash point above 0℃ but below 30℃. d. Kerosene, petrol, turpentine, isoamyl alcohol, acid vinegar and other substances with a flash point higher than 30℃ but lower than 65℃.
1.4 Flammable gases: Hydrogen, acetylene, ethylene, methane, ethane, propane, butane and other gases that can burn at 1 atmosphere at 15°C.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Constant Temperature And Humidity Climate Chamber 225L Humidity Climate Chamber IEC 60068 Environmental Test Chamber |
![]() |
IEC 60950 Heating Cabinet for Electronics Safety Testing 225L Temperature RT+10°C ~300°C |
![]() |
Explosion-proof Walk-In High and Low Temperature Humidity Test Chamber 8.36m³ |
![]() |
IEC 60068-2-78 Walk-in Temperature and Humidity Test Chamber 3.38m³ Temp. -40~+100℃ |
![]() |
ISO 4892-1/2 Water-Cooled Xenon Weathering Test Chamber Irradiance Range 0.3W/M2~1.1 W/M2 |
![]() |
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa |
![]() |
80L Air-Cooled Thermal Shock Test Chamber -40°C To +150°C Test Range |