China Electrical Appliance Testing Equipment manufacturer
Sinuo Testing Equipment Co. , Limited
Testing Equipment Manufacturer
8
Home > Products > Energy Efficiency Lab >

ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations

ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations

Brand Name Sinuo
Model Number SN332-6
Certification Calibration Certificate (Cost Additional)
Place of Origin China
Minimum Order Quantity 1
Price Tailored
Payment Terms T/T
Supply Ability 1 Set Per Month
Delivery Time 2 Months
Packaging Details Plywood
Applied Standards ISO 15502, IEC 62552,etc.
Applied UUT Household Refrigerating Appliances
UUT Range 210L~550L
Chamber Doors 1200×2500mm
Test Station 6 stations
Control Method Computer & software
Temperature 10~55℃
Humidity 25%~95%
Detailed Product Description

 

ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations

 

Overview:

This refrigerator performance lab is designed and manufactured as one testing chamber. The Freezing Capacity, Energy consumption and other performances of refrigerator are tested by means of testing the lab parameters, such as temperature, and electrical performance. This installation can be used to test the performance of 6 Household vertical refrigerators or 2 Chest freezers, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development.

 

In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports.

 

Standards:

Design and Testing according to the following standards:

► ISO 15502: 2005(ISO 5155, ISO 7371, ISO 28187, ISO 8561)

► IEC 62552-1,IEC 62552-3

► SASO 2664

► Other standards can be customized

 

Types of UUT :

Refrigerator:

-Testing Capacity Range:210L ~550L

-Figure size:Maximum Type:W:600mm D:700mm H:2050mm

-The electric parameter:

-Single phase power: 0~1kW

-Single phase voltage: 0~300V

-Single phase current: 0~5A

-Frequency: 50/60Hz

-Power factor: 0.5~1

Chest freezer:

-Testing Capacity Range:210L ~550L

-Figure size:Maximum Type:W:1878mm D:680mm H:890mm

-The electric parameter:

-Single phase power: 0~1kW

-Single phase voltage: 0~300V

-Single phase current: 0~5A

-Frequency: 50/60Hz

 

Testing Contents:

► Storage Temperatures

► Cooling Speed

► Energy consumption

► Freezing Test (Base ISO 15502:2005)

► Load Temperature rise time

► Ice Making Capacity,Freezing Capacity

► Voltage, Current, Power, Power factor

► Working coefficient

*Detailed test method and calculation according to the standards.

 

Temperature and humidity conditions

 
 Test Chamber
Temperature(℃)5~55
Relative humidity(RH)30%~95%
Temperature Stability(℃)≤±0.3
Temperature gradient(℃/m)≤1.0
Humidity Accuracy(RH)≤±3%
Air velocity(m/s)<0.25
NoteThe combination of the above mentioned should not have obviously difference with the Standard.
When the temperature below 16 ℃, humidity control are not required.
When the temperature is higher than 40 ℃, humidity control are 85%RH or less.
 
 
 

Product Tags: Household Refrigerating Appliances Performance Lab   6 Stations Appliances Performance Lab  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Sinuo Testing Equipment Co. , Limited
Subject:
Message:
Characters Remaining: (80/3000)