Model | BF9636H |
Test Contents | AC and DC withstand voltage, insulation resistance |
Data storage method | USB (optional) |
External interface | Alarm LAMP, PLC, RS-232 |
AC withstand voltage |
Output voltage setting range / accuracy | AC 200~5000V ±(1.5%×setting+5digits) |
Breakdown current measurement range / accuracy | 0.10~100.0mA ±(1.5%×setting+5digits) |
Breakdown current preset alarm range | Upper limit :0.1~100.0mA; Lower limit :0.00~5.00mA |
Short-circuited current capacity | ≥200mA (the device will enter into protection status when
short-circuited current exceeds 200mA) |
Test time range / resolution | 1~300s 1s/step |
DC withstand voltage |
Output voltage setting range / accuracy | DC 200~5000V ±(1.5%× setting +5 digits ) |
Breakdown current measurement range / accuracy | 0.10~10.00mA ±(1.5%×display+5 digits) |
Breakdown current preset alarm range | Upper limit: 0.10~10.00mA; lower limit: 0.00~5.00mA |
Test time range / resolution | 1~300s 1s/step |
Insulation resistance |
Output voltage setting range / accuracy | DC500/1000V ±(1.5%× reading +5 digits ) |
Insulation resistance measurement range / accuracy | 1~2000MΩ: ≤100MΩ:± (5%×display+3 digits ) >100 MΩ:± (8%× display +8 digits) |
Insulation resistance alarm setting range | Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ |
Test time range / resolution | 1~300s 1s/step |
Equipment dimensions | 435MM(W)*150MM(H)*550MM(D) |
Equipment weight | Approx. 30KGS |
Equipment accessories | Power cord*1, high voltage probe*1, test wire*1, fuse*1 |