IEC 60335 Clause 7 Dual Station Label Marking Abrasion Test Apparatus
|
IEC 60335 Dual Station Label Marking Abrasion Test Apparatus
Standards For Dual Station Label Marking Abrasion Test Apparatus:
This label marking abrasion test apparatus conforms to IEC 60335-1 clause 7.14, IEC 60065:2014 clause 5.1, IEC 60950:2013 clause 1.7.11, IEC 60669-1 clause 8.9.
Technical parameters For Dual Station Label Marking Abrasion Test Apparatus:
Maintenance Notes For Dual Station Label Marking Abrasion Test Apparatus:
1 The instrument must be placed on a stable surface before use. 2 It is not allowed to move the machine during use. 3 Select the appropriate power supply voltage, should not be too high, to avoid burning the instrument. 4 If the instrument works abnormal, please contact with us for timely processing. 5 The instrument must be used in a good ventilation environment. 6 Please add lubricating oil to the mechanical transmission part in time due to the large operating load of each component of the button mechanism. 7 After each test is completed, operator should clean the machine. 8 The control box part must be wiped with a dry cloth.
Troubleshooting For Dual Station Label Marking Abrasion Test Apparatus:
1 If the POWER is turned on, the instrument is not powered on or the power indicator is not light: if the power indicator is damaged, replace the indicator; if there is no power output at the power output terminal, please check the power cord or power socket-outlet. 2 If the power is turned on, the power indicator lights, but the machine does not work when operator presses the SWITCH button. Please check whether there is a disconnection. If there is a disconnection, please connect it in time. If there is no disconnection of the relay, indicating that the counter is damaged, the counter should be replaced in time. 3 When the number of times set on the counter is finished, but the motor does not stop working, indicating that the counter is damaged. 4 If the power indicator light is on but the counter has no display, it means that the counter is damaged and the counter needs to be replaced.
Configuration
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: IEC 60950 Abrasion Test Apparatus Dual Station Abrasion Test Apparatus Label Marking Abrasion Test Apparatus |
![]() |
IEC 62196 Computer Controlled Overvoltage Test System For Electric Vehicle Accessories |
![]() |
Screwless Terminal Clamping Capacity Test Apparatus IEC 60884-1 Clause 12.3.11 |
![]() |
IEC60335-1 Vacuum Cleaner Hoses Current-Carrying Hoses Flexing Test Device 5 Station |
![]() |
IEC 61855 Figure 13-14 Hair Straightener Tension Uniformity Tester With Graph Illustrated |
![]() |
BS1363-2 Temperature Rise Test System With Dummy Front Plate Max. 45A |
![]() |
6-100KN Box Compression Tester For Carton Packaging Compressive Strength Testing |