IEC60529 IP5/6 Sand And Dust Environmental Test Chamber 1000L
|
|
IEC60529 IP5/6 Sand and Dust Environmental Test Chamber 1000L
Standards & Clauses:
IEC60529:2013 “Degrees of protection provided by enclosure (IP code)” IP5 & IP6 IEC60598-1:2014 “Luminaries-Part1: General requirements and tests”
Technical Parameters:
Details: a. Fine dust: below 75um b. Coarse dust: below 150um c. The dust concentration in the chamber and pipeline is 2kg/m³ d. Air velocity: less than 2m/s (adjustable) e. The amount of talc powder: Prepared according to standard requirements (prepared by user, at least 2KG for the first time, as talc powder is not allowed to ship internationally) f. PLC and touch screen intelligent control system g. PT100 sensor h. Over temperature protection function i. Power phase loss protection j. Leakage circuit breaker k. Power supply: Three phase AC380 V / 50Hz l. Door: Tempered glass door m. Vacuum pump: 60-600L/H n. Controller: using programmable controller (this controller has the following multiple arbitrary setting control functions): ① Dust blowing time (stop, blowing) h/m/s adjustable ② Cycle period: arbitrarily adjustable ③ Preset test time: 0s~999h99m99s, arbitrarily adjustable ④ Power supply: off-on-off o. Metal screen size: nominal wire diameter 50um, nominal distance between wires 75um or less than 150um p. Fan: All plastic centrifugal fan
Remarks: This test chamber can meet the requirements of degrees of protection provided by enclosures of household appliances, low-voltage electrical appliances, automobile, motorcycle parts and etc.
Structure and Panel Description:
The structure and working principle of the dust test chamber are the same as IEC60529-2013, and equipped with an additional airflow heating device, in order to facilitate the use in the case of low ambient temperature or high humidity. When the system is working, operator first puts the dried standard talc powder (2kg/M3) into the dust test chamber, then puts test sample into the dust test chamber, and then starts the fan to make a high-density dust mist formed in the chamber until the preset test time is reached (Usually 8h).
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: IEC60529 Environmental Test Chamber 1000L Environmental Test Chamber Sand And Dust Environmental Test Chamber | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
IEC 60068-2-52 270L Salt Spray Test Chamber For Corrosion Resistance Testing Environmental Tester |
|
UV-A / UV-B Chamber Type Accelerated Weathering Test Chamber For Materials |
|
IP5X IP6X Sand And Dust Test Chamber 1000L With PLC Control Figure IEC 60529 |
|
IP5X & IP6X Sand Dust Test Chamber For Enclosure Sealing Performance Test IEC 60529 |
|
IEC 60529 Fig 2 IP5X And IP6X Sand And Dust Test Chamber 2000L PLC Control |
|
IEC 60068-2-11 Salt Spray Corrosion Test Chambers 108L Corrosion-resistant Construction |