China Electrical Appliance Testing Equipment manufacturer
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
7
Home > Products > IEC 62368 Test Equipment >

IEC 62368-1 Clause 5.4.1.10 Vicat Softening Temperature Determination Tester

IEC 62368-1 Clause 5.4.1.10 Vicat Softening Temperature Determination Tester

Brand Name Sinuo
Model Number SN300FA
Certification Calibration Certificate (Cost Additional)
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms L/C, T/T
Supply Ability 30 Sets Per Month
Delivery Time 20 Days
Packaging Details Standard Exporting Boxed
Applied standard IEC 62368-1
Applied clause 5.4.1.10
Fuel tank capacity 12.5 liters
Heating rate 120±10℃/h (12℃±1℃/6min) , 50 ± 5℃/h(5℃±0.5℃/6min
Temperature error ±1℃
Deformation error ±0.01mm
Detailed Product Description

 

IEC 62368-1 Clause 5.4.1.10 Vicat Softening Temperature Determination Tester

 

Product Information:

This test apparatus designed and manufactured according to the standard of IEC60065:2014 clause 7.2 and table 3, ISO75-1, ISO306.

It is mainly used for the determination of thermal deformation temperature and Vicat softening point temperature of non-metallic materials such as plastics, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high-strength thermosetting extrusion materials, etc. Which is widely used in colleges and universities, scientific research units and product quality supervision and inspection units.

The instrument adopts PLC (programmable controller), touch screen display and operation, and the modular design temperature control unit, which make the performance of the instrument more stable and the operation easier and more convenient.

During the operation, operator only inputs the specimen size, the standard deflection and required weight of the test will be automatically calculated out, avoiding human calculation errors.

The test process can be completed by following the displayed prompts, with high degree of automation, low failure rate, and simple maintenance. It is an advanced instrument used for the determination of thermal deformation and vicat softening point temperature of non-metallic materials.

 

Technical Parameters:

Applied standardIEC 62368-1
Applied clause5.4.1.10
Temperature rangeRoom temperature -300℃
Heating rate

120±10℃/h (12℃±1℃/6min)

50 ± 5℃/h(5℃±0.5℃/6min)

Temperature error±1℃
Deformation error±0.01mm
Minimum resolution of temperature0.1℃
Minimum resolution of deformation0.001mm
Load range0.864N-49.03N
Load error±0.5%
Support span64-100mm continuously adjustable
Heating power3KW
Power supply voltageAC220V/50Hz
AC220V/50HzMethyl silicone oil (the flash point temperature of the medium should be higher than the maximum test temperature)
Cooling methodNatural cooling above 150℃, water cooling or natural cooling below 150℃
This machine has a horizontal host, and its dimensions560×620×640
Fuel tank capacity12.5 liters
 

 