IEC 62368-1 Annex S Horizontal and Vertical Burning Test Apparatus Product information: The Horizontal and Vertical Burning Test Apparatus is required by
IEC 62368-1:2018 Annex S, IEC 60950:2013 clause 4.7.3,
IEC60065:2014 clause 14.1, 20.2.1, 20.2.4, Annex G, IEC60335-1
clause 30, etc. It is also applicable in the horizontal, vertical flammability test
of the relative combustion characteristic of foam plastics whose
density is no-less than 250kg/m according to ISO845 test method. It simulates the influence of early-stage flame when there is a
fire around the electric and electronic products, so that to judge
the igniting danger degree. It is mainly used in plastic and other
non-metallic material sample, solid material. It is also applicable
in the Horizontal, vertical flammability test of the relative
combustion characteristic of foam plastics whose density is no-less
than 250kg/m according to ISO845 test method. Technical Parameters: Applied standard | IEC 62368-1 | Applied clause | Annex S | Working voltage | 220V/50Hz | Power/grade | 50W and 500W double power switching | Control method | PLC control, 7-inch color touch screen operation, with infrared
remote controller | Blast burner | Inner diameter:Φ9.5±0.3mm,length:100mm,made of brass | Gas pressure | 0.1MPa | Gas flow | 50W:105±5ml/min or 18±1mm;500W:965±30ml/min or 117±3 mm,flow meter
adjustment | U type pressure gauge back pressure water column height | 50W:10mm; 500W:125±5 mm | Test angle | 50W: 0°,45°; 500W: 20° | Burning time | 0-9999X0.1S Can be preset | Burning times | 0-9999 times,Can be preset | Residual flame/Residual glow | 0-9999X0.1S Can be displayed | Test flame calibration | Temperature measuring copper head:50W:Ф5.5mm±0.01mm,weight before
drilling 1.76 ± 0 .01 g;500W:Ф9mm±0.01mm,weight before drilling 10
± 0 .05g | Thermocouple: The American original Omega φ0.5 armour
nickel-chromium/nickel aluminum wire K-Thermocouple, temperature
resistance 1100° | Distance between the Bunsen burner port to temperature measuring
copper block:50W: 10±1 mm; 500W: 55±1 mm | Flame height:50W: 20±2mm(there is no internal and external flame);
500W: Inner flame:40±2mm,Outer flame:125±10mm | Temperature rise time from100±2°to 700°±3°50W: 44±2S; 500W: 54±2S | Lighting | Equip with lighting in the test chamber, with control | Test chamber and dimension | > 0.75 cube, black inwall, with exhaust fan,
dimension:1100*550*1200mm, 140kg |
|