60K BTU Double Code Air - Enthalpy Method Calorimeter ISO 5151
|
60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151
System introduction: This air enthalpy method calorimeter lab consists of 1 indoor side room (Room A) and 1 outdoor side room (Room B). The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab parameters, such as temperature, pressure and electrical performance. This installation can be used to test the performance of various window type, split type, free-standing type and ceiling cassette type and duct type AC air conditioners, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development. The laboratory is equipped with two stations, which can simultaneously test two sets of 1-Phase prototypes not larger than 30KBtu (to ensure total not large than 60K BTU), if only test one set of prototype once, then prototype can up to 60K BTU, but should not larger than 60K BTU.
In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports. Testing items:► Rated cooling capacity (T1, T2, T3). ► Rated heating capacity (High, Low, Extra-low) ► Airflow ► Dehumidification capacity ► Input power ► EER(COP) ► Frequency ► Current ► Voltage Types of UUT and environment:► Types of unit under test (UUT) -Split type -Window type -Free-standing type -Ceiling cassette type -Duct type -Inver-frequency air condition
► Measurement range of UUT -Testing Capacity Range: -Total Cooling Capacity: 6000~60000Btu/h A station Cooling Capacity: 6000~60000Btu/h B station Cooling Capacity: 6000~30000Btu/h -Heating Capacity: 6000~60000Btu/h A station Heating Capacity: 6000~60000Btu/h B station Heating Capacity: 6000~30000Btu/h
-Range of air flow: -Air Flow A : 300~4000 m³/h Air Flow B : 200~2000 m³/h -Figure size:Window Type:W:Under 1000mm D:Under 800mm H:Under 1000mm Split Type:W:Under 1000mm D:Under 500mm H:Under 2000mm -The electric parameter: -Single phase power: 0~5kW -Single phase voltage: 0~300V -Single phase current: 0~20A -Frequency: 50/60Hz -Power factor: 0~1
Sinuo is a diversified high-tech enterprise integrating testing equipment, scientific research and teaching equipment, and various non-standard customized equipment, integrating independent R&D and design, production and sales, installation and commissioning, and after-sales maintenance. Our technical staff has accumulated a wealth of practical experience.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 60K Air Enthalpy Method Calorimeter ISO 5151 Air Enthalpy Method Calorimeter |
![]() |
IEC 60456 Washing Machine-Dishwasher-Water Heater Energy Efficiency Test System |
![]() |
IEC 60879 Tower Fan Table Fans Energy Efficiency Performance Test Chamber |
![]() |
IEC 60456 Wahing Machine & Dishwasher Performance Test Chamber 4 Test Stations |
![]() |
BS EN 60456 Washing Machine Energy Efficiency Test System |
![]() |
IEC 61855 Figure 9 Dryer Air Volume Test System For Air Volume Testing Computer Operation |
![]() |
IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance |