Steam Sterilizer Moisture Resistance Test Apparatus IEC 60335-2-15 Figure 101
|
IEC 60335-2-15 Figure 101 Steam Sterilizer Spillage Test Apparatus
Product overview: The spillage test apparatus is designed and manufactured according to IEC 60335-2-15 clause 15.2 figure 101, and IEC60320-1 clause 14.2 figure B.1. It is intended for checking the weight of the protective measures against liquid overflow to ensure that the structure of the plug-in connector (cordless electric kettle) is not affected by liquid when it is installed in an alternative voltage base following the manufacturer’s installation instructions.
Technical parameters:
How to process the moisture resistance of steam sterilizers? Steam sterilizers are placed on a horizontal surface and ml of water containing approximately 1% NaCl is poured onto the top rim in the most unfavourable place. The solution is poured steadily through a tube having an inner diameter of 8 mm over a period of 2 s, the lower end of the tube being 200 mm above the appliance.
|
||||||||||||
Product Tags: Figure 101 Moisture Resistance Test Apparatus 8mm Moisture Resistance Test Apparatus |
![]() |
Vertical Impact Test Platform For 3D-Printed Samples Impact Resistance |
![]() |
Single Phase Programmable AC Power Source 5KVA – 0-300V 40-499.9Hz LED Display |
![]() |
IEC 60335-2-6 Spark Ignition Tester for Pyrolytic Oven Vent Gas Ignition Detection |
![]() |
IEC 62196 Computer Controlled Overvoltage Test System For Electric Vehicle Accessories |
![]() |
IEC 62262 IK Code High Energy Pendulum Hammer Impact Test Apparatus |
![]() |
Screwless Terminal Clamping Capacity Test Apparatus IEC 60884-1 Clause 12.3.11 |