IEC 62133 Battery Testing Equipment Thermal Cycling Low / High Temperature Exposure Test
|
|
IEC 62133 Cell Battery Thermal Cycling Low and High Temperature Exposure Test Chamber
Overview:
This low and high temperature cycling test equipment is mainly used for electric and electronic products, components and other materials' high low temperature test, temperature alternating, damp heat test, environment simulate reliability test, etc.
This test equipment adopts programmable high accuracy microcomputer controller, 7-inch TFT color LCD touch screen, and Intelligent software, which can achieve easy and humanized operation.
Standards Compliant:
It conforms to IEC62133:2017 clause 7.2.4, IEC62133:2012 clause 7.2.4, IEC60086-4 clause 6.4.2 etc.
Technical Parameters:
How is the differences of the thermal cycling test procedures between IEC 60086-4 and IEC 62133-1?
Test Procedure as per IEC 60086-4:2014 clause 6.4.2:
Test cells and batteries shall be stored for at least 6h at a test temperature of 72 ℃, followed by storage for at least 6 h at a test temperature of -40 ℃. The maximum time for transfer to each temperature shall be 30 min. Each test cell and battery shall undergo this procedure 10 times. This is then followed by storage for at least 24 h at ambient temperature. For large cells and batteries the duration of exposure to the test temperatures shall be at least 12 h instead of 6 h.
Test Procedure as per IEC 62133-1:2017 clause 7.2.4:
Fully charged cells or batteries are subjected to temperature cycling (-20 ℃, +75 ℃), in forced draught chambers, according to the following procedure. Step 1: Place the cells or batteries in an ambient temperature of +75 ℃ ±2 ℃ for 4 h. Step 2: Change the ambient temperature to 20 ℃ ±5 ℃ within 30 min and maintain at this temperature for a minimum of 2 h. Step 3: Change the ambient temperature to -20 ℃ ±2 ℃ within 30 min and maintain at this temperature for 4 h. Step 4: Change the ambient temperature to 20 ℃ ±5 ℃ within 30 min and maintain at this temperature for a minimum of 2 h. Step 5: Repeat steps 1 to 4 for a further four cycles. Transition from Step 4 to Step 1 within 30 min. Step 6: After the fifth cycle, store the cells or batteries and conduct a visual check after a rest period of at least 24 h.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: battery charge discharge test equipment battery discharge analyzer | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
IEC 63370 Clause 19.10 Battery Pressure Test Chamber PLC-Controlled Safety Enclosure System |
|
IEC 62133 Battery Explosion-Proof Constant Temp & Humi Test Chamber -40℃~150℃ |
|
IEC 60335-1 Appendix BB-20.1 Battery Case Pressure Testing System for Prismatic Cells Test |
|
IEC 62133-2 Battery Internal Short Circuit Tester with Temperature & Force Control |
|
UL 2580 Clause 26 Temperature Controlled External Short Circuit Tester With High Current 2000A |
|
IEC 62133 Electromagnetic Vibration Test System For Battery Testing |