Weatherproof Request To Exit Motion Detector , Rex Motion Sensor 12-24VDC
|
Detailed Product Description
|
Weatherproof Request To Exit Motion Detector , Rex Motion Sensor 12-24VDC
DESCRIPTION The OD-22 passive infrared Sensor is specifically designed for
to-exit applications , Standard OD-22 include qualified motion
analysis. The OD-22 may be mounted toframe header,wall or ceiling.
Intended for indoor use only. FEATURES • Adjustable second time delay • Micro-based signal processing • High sensitivity • Available in white or brown enclosure 1. SPECIFICATIONS
2. DIMENSIONS 3. DESCRIPTION AND OPERATION 4. DETECTION PATTERN
5. INSTALLATION Mounting Procedure 1. Select a mounting location over the center of the door or doors
to be covered. The target must walk directly toward the detector.Mount the detector on the
ceiling,wall,or door frame. 2. Remove the front cover from the detector. 3. Route the wiring as necessary through the wiring entrance(refer
to the item 3 description and oper- ation).For surface wiring,use
the break out wiring entrance on the front cover(at the same end as
the wire entrance). 4. Loosely mount the back cover to the mounting sur- face using the
supplied mounting screws. 5. Aim the detector for the desired coverage. 6. Mount the front cover on the detector. Long Range/Short Range Adjustment The OD-22 can be set to detect individuals at either a long
rang(several steps from the door) or at short range (immediately in
front of the door).If the build- ing includes a lengthy approach to
the exit doorway and no other foot traffic in the area, choose the
long range setting. Setup and Testing 1. Apply power to the unit. 2. Wait at least 3 min for the detector to settle. 3. Test the unit by walking directly throgh the coverage area,to-
ward the door. 4. Aim the detector up or down if necessary to obtain the proper
coverage. 5. Check that the relay latch time is sufficient Adjust if
necessary. 6. After confirming proper operation,replace the cover and walk
test one more time to ensure the coverage has not changed. 6. WIRING Latch Time DIP Switch 1,2,and 3 set the relay time.Latch time is adjustable
from 0.5 sec to 64 sec.It indicates the amount of time the relay
can remain active after the detector first sees motion. > >>
7. TROUBLE SHOOTING AND MAINTENANCE >
MAINTENANCE
INSPECTION: An inspection of this unit should be made periodically, consisting
of ,but not limited to all mounting, wiring and the condition of the interior area and components. CLEANING : Clean the plastic parts of this unit with a soft, clean, cloth
dampened with water. TESTING : This unit should be tested rouinely for proper operation. At a
minimum, operation should be fully checked yearly.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: request to exit motion sensor outdoor request to exit motion sensor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Related Products
|
ALEPH OD22 24VDC 30mA Request To Exit Detector Passive Infrared |
|
ALEPH Durable Request To Exit Motion Detector With Wall Or Ceiling Mounted OD22; |
|
Passive Infrared Request To Exit Sensor High Sensitivity , Red Led Indication OD22; |
|
OD22; Specifically Designed Request To Exit Sensor , Rex Motion Detector For Indoor |
|
OD22; High Sensitivity Request To Exit Sensor Passive Infrared Detection Type |
|
Outdoor Request To Exit Motion Sensor With 0.5-64 Seconds Relay Hold Time |
Email to this supplier