Stranded Copper Core Halogen Free Mineral Insulated Cable
|
Detailed Product Description
|
Multi-core MICC mineral insulated cable
Copper core aluminum sheathed flexible mineral insulated cable 1. Conductor: It is made of stranded copper wires with good bending
performance. 2. Insulation: Use high temperature resistant, non-combustible
inorganic insulating materials. 3. Metal shell: made of aluminum alloy. 4. Outer sheath: Use environmentally friendly, aging-resistant,
weather-resistant, low-smoke, and halogen-free sheath materials. 5. Suitable for indoor and outdoor laying, able to withstand
external mechanical forces. Method of choosing 1. In the following cases, flexible mineral insulated cables with
plastic sheaths should be used: The cable is placed in an environment that corrodes the copper
sheath. The cables are buried directly or laid through pipes. The cables are laid in non-technical spaces of buildings and have
aesthetic requirements. Where there is a fire protection
requirement, a halogen-free and low-smoke plastic enclosure should
be used.
2. Specification selection Determine the maximum operating temperature of the cable according
to the cable laying environment, reasonably select the
corresponding cable current, and determine the cable
specifications. 2.1: There are two types of flexible mineral insulated cables
according to the cable temperature Carrying capacity: at 70°C Ampacity at 105°C 2.2: The current carrying capacity of the selected cable should be
in accordance with the normal operating temperature of 70 0 C under
the following laying conditions: Clean lines along walls, brackets, roofs and bridges. It is routed together with other types of cables in the same
bridge, shaft, cable trench, and cable tunnel. Other places where the temperature of the cable sheath is too high
may cause personal injury or equipment damage. 2.3: Place the cables in the bridge, cable trench and the place
where the unmanned machine wears the pipe. The current carrying
capacity can be selected according to the normal operating
temperature 105 0 C . 2.4: The specifications of flexible mineral insulated cables
should be reasonably determined according to the actual length of
the line and the length of delivery of the cable. 3. Design points 3.1 The copper sheath can be used as a ground wire, so PE wire is
usually not needed. 3.2 Replacing bus ducts with flexible mineral insulated cables with
large cross-sections can reduce engineering investment and improve
line safety.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Halogen Free Mineral Insulated Cable Stranded Copper Mineral Insulated Cable OD 10.7mm Mineral Insulated Cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Related Products
|
MI CIA LSZH Mineral Insulated Cable Copper Interlocked Fire Resistance |
|
5 Core Low Smoke Zero Halogen Wire Heat Resistant Environmental Corrosives |
|
Three Wire Mineral Insulated Cable Copper Conductor For Fire Survival System |
|
Industrial Mineral Insulated Cable Mi Thermocouple INCL600 Sheath Low Voltage |
|
Flexible MICC Mineral Insulated Power Cable , Copper Sheathed Cable |
|
Heat Proof High Temperature Resistant Cable Mineral Insulated Smooth PVC Jacket |
Email to this supplier