E26 Go And Not Go Gauges , Mold steel Screw Thread Gauge
|
IEC60061-3 E26 lamp cap gauge, go gauge no go gauge, screw thread gauge
E26 and E26d Gauge list:
Confirms:
Purpose and Testing: “GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d To check the maximum dimensions of the screw thread and dimension
T1min of E26, E26/50x39, E26/51x39 or E26d caps on finished
lamps. When the cap on a finished lamp has been screwed into the gauge as
far as it will go, the central contact shall touch surface X. When
the lamp is removed from the gauge, at least two full turns shall
be required to disengage the threads. “NOT GO” GAUGE FOR CAPS To check the minimum outside (major) diameter of the screw thread,
dimension d, of E26, E26/50x39, E26/51x39 orE26d caps on finished
lamps. When the gauge is placed over the thread of the cap on a finished
lamp, held cap uppermost, the central contact shall not project
beyond surface X. Only the weight of the gauge itself shall be used
in the test. GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS To check lamp dimensions for contact-making in E26, E26/50x39,
E26/51x39 or E26d lampholders. The shape of the lamp with regard to the fit in the lampholder is
assumed to be correct, if the lamp can be pushed into the gauge
until plane W reaches plane V or projects beyond it. For E26/24
capped lamps, when surfaces V and W are coincident, the top of the
cap including any solder or conductive material, shall not extend
above surface X. GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST
ACCIDENTAL CONTACT E26d To check protection against accidental contact of caps E26d on
finished lamps. When the lamp has been pushed into the gauge as far as it will go
with the side solder of the cap located in the recess provided,
surface W of the plunger shall not project beyond surface V. GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS E26d To check dimensions S min., S max., S1min. and S1max. of caps E26d. When the cap (or lamp) has been pushed into the gauge as far as it
will go, surface W of the plunger shall project beyond surface Y,
but for unmounted caps, shall not project beyond surface X. GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS E26d To check dimensions C max. and C1 max. of caps E26d. When the unmounted cap has been pushed into the gauge as far as it
will go, surface W of the plunger shall not project beyond surface
X. For caps on finished lamps, surface W shall not project beyond
surface V. In this instance, the cap shall be so positioned that
the solder on the intermediate contact is located in the recess
provided in the gauge. To check dimensions C1 min, andT1 min,show on sheet 7004-29 and the
maximum dimensions of the cap thread. When the lamp has been screwed into the gauge as far as it will go,
the surface “W” shall be co-planar with or project beyond surface
“V”. After this test, at least two full turns of the lamp shall be
required to disengage it from the gauge. |
||||||||||||||||
Product Tags: E26 Go And Not Go Gauges IEC60061-3 Go And Not Go Gauges SGS Screw Thread Gauge |