High Accuracy 0-100NTU Lower Tubidity Sensor For Industry Treated
Water The Daruifuno OLTU601 redefines liquid turbidity measurement with
its advanced laser flow-through sensor and integrated display. This
innovative device provides instant, on-screen visualization of
turbidity or suspended particle concentration, eliminating the need
for external equipment. Users can directly view precise measurement
values, units, and other critical data on the built-in screen.
How it Works: Precision Laser Scattering Technology At its core, the OLTU601 utilizes the principle of laser light
scattering. A concentrated laser beam penetrates the liquid sample.
As suspended particles within the liquid interact with the laser,
they cause the light to scatter. An integrated light receiver then
accurately detects the intensity of this scattered light. The
direct correlation between scattered light intensity and the
concentration of suspended particles ensures highly accurate and
reliable measurements. Superior Sensitivity and Enhanced User Experience Setting a new standard in turbidity sensing, the Daruifuno OLTU601
offers unparalleled sensitivity and accuracy compared to
traditional sensors. Its reliance on the unique characteristics of
laser beams allows for exceptionally precise measurements, even at
very low turbidity levels. The integrated display significantly
improves user convenience, offering an intuitive interface for
real-time data presentation, which streamlines both operation and
data collection workflows.
Technical Parameters Model | OLTU600 | OLTU601 | Measuring Technology | 660nm Laser Scattering Principle | Measuring Range | Turbidity: 0.001~100NTU Temp: 0~45℃ | Resolution | Turbidity: 0.001NTU Temp: 0.5℃ | Accuracy | 0.001~40NTU is ± 2% of reading or ±0.015NTU, take the larger one;
40~100NTU is ± 5% of reading | Communication | RS485 MODBUS-RTU | Display | LED light | OLED screen | Operation Panel | Via PC or controller | 3 operation buttons | Response Time | Step response, the initial response time<60 seconds | Related Measurement | Temp measurement | Calibration Method | Multi-point calibration; Contrast Offset; Factor offset | Sample Pressure | Ensure that the sample pressure is 1~2bar before the injection port | Sample Flow Rate | 100~700mL/min, ideal flow: 200~300mL/min | Operating Temp | 0~45℃ (does not freeze) | Storage Temp | -10~60℃ | Shell Material | POM+nylon+ABS+stainless steel | Dimension | 140*140*330mm | Installation | Main body wall mount | Lead interface | M12 | Protection Grade | IP65 | Power Supply | 9~18V DC | Power Consumption | 2.5W | Weight | 2100g |
Daruifuno OLTU601: Advanced Laser Flow Turbidity Sensor The Daruifuno OLTU601 flow turbidity sensor leverages a
sophisticated laser light scattering principle for highly precise liquid turbidity measurements. It works by
directing a 660nm laser vertically into the water sample. When this
laser light encounters suspended particles, it scatters. An
integrated silicon photocell receiver, submerged in the water,
accurately detects this scattered light at a 90° angle relative to the original laser beam, allowing for precise
turbidity calculations. Key Advantages and Features: Compact Form Factor: The OLTU601 features a miniaturized design, making it perfect for installations where space is a critical
constraint. High-Resolution Laser Performance: Employing 660nm laser technology, the sensor provides outstanding resolution and a rapid response
time for monitoring dynamic changes in turbidity. Reduced Maintenance Needs: Optional features like a viewing window and an automatic emptying
system significantly lower maintenance requirements, boosting operational efficiency. Minimized Sample Waste: With its low injection flow requirements, the sensor helps minimize the volume of waste generated during
the measurement process. Smart Calibration & Portability: The OLTU601 stores calibration data internally, supporting offline calibration for genuine "plug and play" functionality directly on-site. Integrated Flow Cell Design: This turbidity probe is engineered as a flow cell type, ensuring consistent and reliable interaction with the sample. On-Board Display & Controls (OLTU601): Specifically for the OLTU601 model, an integrated display shows measurement parameters, complemented by three user-friendly
buttons for easy calibration. Digital Connectivity (OLTU601/OLTU600): Both the OLTU601 and OLTU600 models come with RS485 Modbus RTU communication, enabling effortless integration into diverse control systems.
Advantage Benefits of Digital Low Turbidity Sensors Digital low turbidity sensors offer significant advantages across
various applications, delivering enhanced performance and
operational efficiency. Superior Precision and Stability These sensors employ digital technology for both measurement and
data processing, ensuring exceptional accuracy and consistent
stability. This directly translates to highly reliable turbidity
readings, essential for well-informed decisions. Real-time Monitoring and Comprehensive Data Digital sensors excel in real-time monitoring, providing instant
updates on turbidity levels. They also offer robust data logging
capabilities, facilitating thorough historical analysis. This
continuous data flow is crucial for identifying trends, detecting
sudden shifts, and implementing proactive control measures. Adaptable and Customizable A key benefit of digital sensors is their flexibility and
programmability. Users can easily customize parameters such as
measurement ranges, sensitivity, and sampling frequencies to
perfectly align with their specific application needs. This
adaptability ensures optimal performance across diverse operating
conditions. Reliable in Harsh Conditions Digital sensors are engineered with strong interference resistance.
This allows them to maintain stable performance even in complex or
electrically noisy environments, minimizing the impact of external
disturbances on measurement accuracy and ensuring dependable
operation. Seamless Integration and User-Friendly Design Designed for modern systems, digital sensors typically feature
standardized interfaces and communication protocols. This
simplifies their integration with existing equipment and control
systems. Additionally, their user-friendly interfaces streamline
both installation and daily operation, making them accessible to a
wider range of users. Optimized Resource and Cost Efficiency Investing in digital low turbidity sensors leads to long-term
savings. They generally have lower maintenance costs and extended
lifespans. The capability for remote monitoring and fault diagnosis
also significantly reduces downtime, contributing to substantial
overall cost and resource savings. In summary, digital low turbidity sensors provide an impressive
combination of precision, stability, real-time insights,
adaptability, and cost-effectiveness. These attributes make them an
ideal solution for a wide array of applications requiring accurate
turbidity measurement and continuous monitoring.
Low turbidity sensors are often used in environments where high
sensitivity and accuracy are required. Some of these applications
include: - Drinking Water and Wastewater Treatment: In drinking water and
wastewater treatment plants, low turbidity sensors are used to
monitor the concentration of suspended particles and contaminants
in water to ensure that water quality meets relevant standards.
- Pharmaceutical industry: In the pharmaceutical process, low
turbidity sensors are used to monitor tiny particles and impurities
in pharmaceutical solutions or injections to ensure product quality
and purity.
- Winemaking industry: In the winemaking process, low turbidity
sensors are used to monitor the concentration of microorganisms and
suspended particles in the fermentation broth to ensure the quality
and stability of wine products.
- Food Processing: During food processing, low turbidity sensors are
used to monitor the concentration of suspended particles and
impurities in food to ensure food safety and quality.
- Semiconductor Manufacturing: In the semiconductor manufacturing
process, low turbidity sensors are used to monitor tiny particles
and impurities in ultrapure water and chemical solutions to ensure
the accuracy and stability of the chip manufacturing process.
- Biomedical Research: In biomedical research, low turbidity sensors
are used to monitor the concentration and purity of cells,
proteins, and other biomolecules in biological samples to support
scientific experiments and diagnostic applications.
|